Hemodialysis blood access flow rates can be estimated accurately from on-line dialysate urea measurements and the knowledge of effective dialyzer urea clearance.

نویسندگان

  • Robert M Lindsay
  • Jan Sternby
  • Bo Olde
  • Roland Persson
  • Mary Ellen Thatcher
  • Kim Sargent
چکیده

Measurement of blood flow rate (Qa) is used to monitor arteriovenous fistulas and grafts that are used for hemodialysis blood access. Most Qa measurements use indicator dilution techniques to measure the recirculation that is induced by the reversal of hemodialysis blood lines. R plus the dialysis circuit flow (Qb) allows the calculation of Qa. The principle of needle reversal also can be used with a dialysate urea monitor (e.g., DQM 200 [Gambro]) without injection of diluent; the effect of the reversal on urea concentration is observed. Access blood water flow rate (Qaw) in relation to the effective clearance (K) is found from the urea concentrations in the dialysate with needles in the normal (Cn) and reverse (Cr) positions: K/Qaw = (Cn - Cr)/Cr. Qa is calculated by adjusting Qaw for hematocrit and protein. For testing of this theoretical relationship, 20 patients who were dialyzed on Integra (Hospal) and Centrysystem 3 (Cobe) machines that were fitted with DQM 200 were studied. During each treatment, lines were reversed and Qa was measured by ultrasound velocity dilution (Transonic HD01 monitor); at the same time, Cn and Cr were measured by DQM 200 and K was calculated. K1 was determined from a predialysis blood urea concentration (Cb), initial dialysate urea concentration (Cd), dialysate flow rate (Qd), and the relationship K x Cb = Qd x Cd (K1). K was determined separately from a conductivity step method using Diascan (Hospal) attached to Integra machines only (K2). With the use of K1, 127 comparisons were made; a correlation existed (r = 0.916), although Bland-Altman analysis showed that the dialysate urea method gave a mean value 5.3% +/- 15.3 (+/-SD) higher than that of Transonic (P < 0.001). With the use of K2, there also was a correlation of (r = 0.944; n = 63), and Bland-Altman testing showed an NS difference of +3.5% between the dialysate urea and Transonic methods. Qa can be estimated from on-line dialysate urea measurements that are taken before and after line reversal together with knowledge of K.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and β2-microglobulin during clinical haemodialysis

BACKGROUND Diffusive clearance depends on blood and dialysate flow rates and the overall mass transfer area coefficient (K(o)A) of the dialyzer. Although K(o)A should be constant for a given dialyzer, urea K(o)A has been reported to vary with dialysate flow rate possibly because of improvements in flow distribution. This study examined the dependence of K(o)A for urea, phosphate and β(2)-microg...

متن کامل

Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound

Background: Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre.Objective: In This study, the infl...

متن کامل

Effect of Low Dialysate Flow Rate on Hemodialyzer Mass Transfer Area Coefficients for Urea and Creatinine.

Recent work has shown that the dialyzer mass transfer area coefficient (Ko A) for urea increases when the dialysate flow rate is increased from 500 to 800 mL/min. In this study we determined urea and creatinine clearances for two commercial dialyzers containing polysulfone hollow fibers in vitro at 37°C, a nominal blood flow rate of 300 mL/ min, and dialysate flow rates (Qd ) ranging from 100 t...

متن کامل

Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique.

The efficiency of a hemodialyzer is largely dependent on its ability to facilitate diffusion between blood and dialysis solution. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. This article describes the distribution of the blood and dialysate flows in hollow-fiber hemodialyzers analyzed with a computerized scanning te...

متن کامل

Optimal Wavelength Selection in Ultraviolet Spectroscopy for the Estimation of Toxin Reduction Ratio during Hemodialysis

Introduction The concentration of substances, including urea, creatinine, and uric acid, can be used as an index to measure toxic uremic solutes in the blood during dialysis and interdialytic intervals. The on-line monitoring of toxin concentration allows for the clearance measurement of some low-molecular-weight solutes at any time during hemodialysis.The aim of this study was to determine the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 1 5  شماره 

صفحات  -

تاریخ انتشار 2006