Microvascular oxygen tension in the rat mesentery.
نویسندگان
چکیده
Longitudinal Po(2) profiles in the microvasculature of the rat mesentery were studied using a novel phosphorescence quenching microscopy technique that minimizes the accumulated photoconsumption of oxygen by the method. Intravascular oxygen tension (Po(2), in mmHg) and vessel diameter (d, in microm) were measured in mesenteric microvessels (n = 204) of seven anesthetized rats (275 g). The excitation parameters were as follows: 7 x 7-microm spot size; 410 nm laser; and 100 curves at 11 pulses/s, with pulse parameters of 2-micros duration and 80-pJ/microm(2) energy density. The mean Po(2) (+/- SE) was 65.0 +/- 1.4 mmHg (n = 78) for arterioles (d = 18.8 +/- 0.7 microm), 62.1 +/- 2.0 mmHg (n = 38) at the arteriolar end of capillaries (d = 7.8 +/- 0.3 microm), and 52.0 +/- 1.0 mmHg (n = 88) for venules (d = 22.5 +/- 1.0 microm). There was no apparent dependence of Po(2) on d in arterioles and venules. There were also no significant deviations in Po(2) based on d (bin width, 5 microm) from the general mean for both of these types of vessels. Results indicate that the primary site of oxygen delivery to tissue is located between the smallest arterioles and venules (change of 16.3 mmHg, P = 0.001). In conclusion, oxygen losses from mesenteric arterioles and venules are negligible, indicating low metabolic rates for both the vascular wall and the mesenteric tissue. Capillaries appear to be the primary site of oxygen delivery to the tissue in the mesenteric microcirculation. In light of the present results, previously reported data concerning oxygen consumption in the mesenteric microcirculation can be explained as artifacts of accumulated oxygen consumption due to the application of instrumentation having a large excitation area for Po(2) measurements in slow moving and stationary media.
منابع مشابه
Microlymphatic and tissue oxygen tension in the rat mesentery.
Oxygen phosphorescence quenching was used to measure tissue Po(2) of lymphatic vessels of 43.6 +/- 23.1 microm (mean +/- SD) diameter in tissue locations of the rat mesentery classified according to anatomic location. Lymph and adipose tissue Po(2) were 20.6 +/- 9.1 and 34.1 +/- 7.8 mmHg, respectively, with the difference being statistically significant. Rare microlymphatic vessels in connectiv...
متن کاملMicrovascular Hypersensitivlty Subsequent to Chemical Denervation
Microscopic observation and micrometric measurements of microarterial vessels in the mesentery of the anesthetized rat, during chemical interference with the vasomotor nerve supply, showed (A) marked (average 25X) hypersensitization to epinephrine; (B) persistent vasoconstriction; and (C) depression or cessation of vasomotion. These and concomitant similar reactions of the precapillary sphincte...
متن کاملMicrovascular hypersensitivity subsequent to chemical denervation.
Microscopic observation and micrometric measurements of microarterial vessels in the mesentery of the anesthetized rat, during chemical interference with the vasomotor nerve supply, showed (A) marked (average 25X) hypersensitization to epinephrine; (B) persistent vasoconstriction; and (C) depression or cessation of vasomotion. These and concomitant similar reactions of the precapillary sphincte...
متن کاملHematocrit distribution and tissue oxygenation in large microcirculatory networks.
OBJECTIVE Oxygen tension in the brain is controlled by the microcirculatory supply of RBC, but the effect of non-Newtonian blood flow rheology on tissue oxygenation is not well characterized. This study assesses different biphasic blood flow models for predicting tissue oxygen tension as a function of microcirculatory hemodynamics. METHODS Two existing plasma-skimming laws are compared agains...
متن کاملHemoglobin oxygen saturation measurements using resonance Raman intravital microscopy.
A system is described for in vivo noninvasive measurements of hemoglobin oxygen saturation (HbO2Sat) at the microscopic level. The spectroscopic basis for the application is resonant Raman enhancement of Hb in the violet/ultraviolet region, allowing simultaneous identification of oxy- and deoxyhemoglobin with the same excitation wavelength. The heme vibrational bands are well known, but the tec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 294 1 شماره
صفحات -
تاریخ انتشار 2008