Bacterial retention properties of heat and moisture exchange filters.

نویسندگان

  • M G Lee
  • J L Ford
  • P B Hunt
  • D S Ireland
  • P W Swanson
چکیده

We have examined the properties of six heat and moisture exchange filters (HMEF) to ascertain their resistance to liquid flow and their ability to retain a challenge bacterium, Pseudomonas diminuta, from aqueous and nebulized suspensions. Only one HMEF, the Pall Ultipor was able to withstand a significantly greater pressure of liquid than that found in clinical practice. However, when breached, the HMEF were unable to prevent transmission of micro-organisms from aqueous suspension. Only the Darex Hydrobac filter failed to meet the manufacturer's claim for filter efficiency for nebulized bacteria, mainly because the filter housing failed under test. When the reduction in bacterial cells after passage of the nebulized Pseudomonas diminuta through the HMEFs was analysed statistically, the data showed that the HMEF produced by Pall (Ultipor) and Intersurgical (Filter therm) were superior to those produced by DAR Mediplan (Hygrobac), Intertech (HME 225-2835-800) and Gibeck (Humid-vent).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of heat-moisture treatment on physicochemical properties of wheat starch

Abstract Heat-moisture treatment is a physical method for starch modification to improve its functional properties depending on the application. The functional characteristics of the heat-moisture treated starch depend upon the source of starch and treatment conditions including time and temperature. The main objective of this study was to determine the functional properties of heat-moisture tr...

متن کامل

A breathing filter exchanging heat and moisture prevents asthma induced by cold air.

In order to devise a protective aid against bronchial obstruction induced by cold air, we have tested a breathing filter with heat and moisture exchanging properties. Nine asthma patients, who all had a history of cold-induced asthma, took part in exercise tests on an ergometer bicycle at a temperature of approximately -10 degrees C, without and with a breathing filter. Without a breathing filt...

متن کامل

Microbiological safety and cost-effectiveness of weekly breathing circuit changes in combination with heat moisture exchange filters: a prospective longitudinal clinical survey

AIM To assess the safety and cost effectiveness of a usage for seven days of breathing circuit systems (BCSs) in combination with heat moisture exchanger filters (HMEF) in operation room anesthesia. METHOD In a prospective longitudinal clinical study, the contamination on high-risk surfaces (HMEF together with inner and outer surface of BCS) was monitored over 1, 2, 5, and 7 days. RESULTS of ...

متن کامل

Performance of breathing filters under wet conditions: a laboratory evaluation.

INTRODUCTION Heat and moisture exchangers in combination with a bacterial and viral filter (HMEF) are widely used during general anaesthesia. Excess patient secretions occluding the HMEF have been responsible for previous case reports of airway obstruction. A previous study suggested that differences in HMEF design might contribute to filter obstruction under wet conditions. METHODS We tested...

متن کامل

Applications of Lactobacillus rhamnosus spent culture supernatant in cosmetic antioxidation, whitening and moisture retention applications.

This study was aimed at investigating the antioxidant, whitening, and moisture-retention properties of Lactobacillus rhamnosus spent culture supernatant (Lr-SCS) in cosmetic applications. Results reveal that Lr-SCS effectively and gradually scavenges 1,1-diphenyl-2-picrylhydrazyl as well as 2,2-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid) radical cations, and increases reducing power in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 69 5  شماره 

صفحات  -

تاریخ انتشار 1992