Determination of copper in whole blood by differential pulse adsorptive stripping voltammetry

نویسندگان

  • Tarik Attar
  • Yahia Harek
چکیده

A selective and sensitive method for determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The method is based on adsorptive accumulation of the complexes of Cu (II) ions with benzenesulfonyl hydrazide onto hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed species by differential pulse cathodic stripping voltammetry. The effect of various parameters such as supporting electrolyte, concentration of benzenesulfonyl hydrazide, accumulation potential, accumulation time and stirring rate on the selectivity and sensitivity were studied. The optimum conditions for determination of copper include perchloric acid 0.03 M, concentration of benzenesulfonyl hydrazide 7.5×10 -5 M, the accumulation potential of -350 mV (vs. Ag/AgCl), the accumulation time of 50 s, and the scan rate of 50 mV s -1 . Under optimized conditions, linear calibration curves were established for the concentration of Cu (II) in the range of 0.62-275 ng mL -1 , with detection limit of 0.186 ng mL -1 for Cu (II). The procedure was successfully applied to the determination of copper ion in whole blood samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of trace amounts of lead by adsorptive cathodic stripping voltammetry in the presence of xylenol orange

Lead forms the complexes with xylenol orange in the basic solution. An adsorptivedifferential pulse stripping method for the determination of lead is proposed. The procedureinvolves an adsorptive accumulation of lead on a hanging mercury drop electrode (HMDE) inthe presence of xylenol orange, followed by reduction of adsorbed lead by voltammetric scanusing differential pulse modulation. The opt...

متن کامل

Simultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid

In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Determination of ultra trace of thiosemicarbazide by adsorptive stripping voltammetric method

In the present work, an adsorptive stripping voltammetric method using a hanging mercurydrop electrode (HMDE) was described in order to determine the ultra trace of thiosemicarbazidein different real samples. The method is based on accumulation of thiosemicarbazide on mercuryelectrode. The potential was scanned to the negative direction and the differential pulse strippingvoltammograms were rec...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014