Systematic Testing of Radiotherapy Accelerators

نویسنده

  • Kenneth J. Turner
چکیده

The nature of radiotherapy accelerators is briefly explained. It is argued that these complex safety-critical systems need a systematic basis for testing their software. The paper describes a novel application of protocol specification and testing methods to radiotherapy accelerators. It is explained that the accelerator control system is specified using LOTOS (Language Of Temporal Ordering Specification). It is completely infeasible to use the LOTOS directly for test generation. Instead, specification inputs are restricted using annotations in a Parameter Constraint Language. This is automatically translated into LOTOS and combined with the accelerator specification. It then becomes manageable to generate tests of the actual accelerator to check that it agrees with its specification according to the relation ioconf (input-output conformance). Test annotations and a sample test are described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protocol Techniques for Testing Radiotherapy Accelerators

The nature of radiotherapy accelerators is briefly explained. It is argued that these complex safety-critical systems need a systematic basis for testing their software. The paper describes a novel application of protocol specification and testing methods to radiotherapy accelerators. An outline specification is given in LOTOS (Language Of Temporal Ordering Specification) of the accelerator con...

متن کامل

Formally-Based Testing of Radiotherapy Accelerators

The paper presents the aims and research plan of the CONFORMED project (Conformance Of Radiological/Medical Devices). This three-year project will develop tools and techniques for modelling and testing radiotherapy equipment. Formal specifications in LOTOS (Language Of Temporal Ordering Specification) will be used to model accelerators formally and to derive tests rigorously based on these spec...

متن کامل

بررسی وضعیت شتاب‌دهنده خطی الکترون در درمان سرطان در ایران

Medical electronlinear accelerators are the most practical radiotherapy facilities in cancer treatment. About 52 percent of patients are treated by these radiotherapy systems during their treatment process. However, in developing countries there are not enough systems and recent studies reported the shortage of 5000 megavoltage radiotherapy accelerators all over the world. According to internat...

متن کامل

COMP report: CPQR technical quality control guideline for medical linear accelerators and multileaf collimators

The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The ...

متن کامل

The dosimetry assessment of Varian Linear Accelerators of 6, 15 and 20 MV by Monte Carlo Method

 Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are prov...

متن کامل