“Scalpel safety”: Modeling the effectiveness of different safety devices’ ability to reduce scalpel blade injuries
نویسندگان
چکیده
Background: The objective of this study was to analyse and compare the potential effectiveness of two safety strategies in reducing scalpel blade injuries. The two strategies examined were safety scalpel vs. a single-handed scalpel blade remover combined with a hands free passing technique (HFPT) (e.g. passing tray or neutral zone). Methods: This was a retrospective study involving review of a 550-bed adult metropolitan tertiary referral hospital’s sharps injuries database, chart review, and hypothetical modelling of the data to determine potential preventable injuries. The modelling was done twice, firstly assuming 100% effectiveness of each safety device and secondly using previously published activation rates for “active” safety devices which were considered to be a more accurate reflection of real-life work practices. Results: A total of 141 scalpel injuries were reported between 1987 and 2003. Clinical charts were reviewed for 137 of these injuries. Just under 50% of injuries were sustained while the scalpel was in use and these were assumed to be not preventable. Assuming 100% effectiveness for each safety device resulted in 72 injuries being prevented by safety scalpels and 69 injuries being prevented by a combination of a single-handed scalpel blade remover and an HFPT. When injury prevention was calculated using published data on activation rates for “active” safety devices, the number fell to as low as 12 for safety scalpel and to 61 for the combination of a single-handed scalpel blade remover and an HFPT. Conclusion: Both safety strategies are potentially effective in reducing scalpel blade injuries. However the safety scalpels are active devices and as such are subject to widely variable activation rates. We recommend use of a single-handed scalpel blade remover in combination with an HFPT as this can potentially prevent 5 times as many injuries as safety scalpels.
منابع مشابه
ADVANCES IN EXPOSURE PREVENTION A Publication for the Prevention of Occupational Transmission of Bloodborne Pathogens Suture Needle and Scalpel Blade Injuries
MOST REPORTS ON PERCUTANEOUS INJURIES among health care workers focus on hollow-bore needle devices such as syringes, blood-drawing devices, and vascular access devices. One reason is that the majority of reported percutaneous injuries in health care settings are caused by hollowbore needles. In 58 U.S. hospitals participating in an EPINet data-sharing group from September 1992 through August 1...
متن کاملRetrieval of a retained broken scalpel blade from lumbar intervertebral disc space - a case report
Lumbar diskectomy is a common procedure in neurosurgery, besides the common complications broken scalpel blade during disc removal is a rare event. Usually retrieval of such sharp retained fragments in same sitting is difficult and to prevent further complications another session is warranted [1]. We report a case of broken scalpel blade during L1-L2 lumbar intervertebral disc removal and succe...
متن کاملDevelopment of a canine model for recurrent laryngeal injury by harmonic scalpel
Various energy devices had been used in thyroid surgery. Aim of study is to develop canine model for recurrent laryngeal nerve injury by harmonic scalpel and to evaluate feasibility of using this model for evaluating the safety use of harmonic scalpel during thyroid surgery. Nine dogs were divided into 3 groups according to distance between harmonic scalpel application and recurrent laryngeal n...
متن کاملPercutaneous release of the A1 pulley: a cadaver study.
PURPOSE Percutaneous release of the A1 pulley has been used for treatment of trigger fingers with success. However, lack of direct visualization raises concerns about the completeness of the release and about potential injury to the tendons or neurovascular structures. The purpose of this study was to assess the efficacy and safety of percutaneous release of the A1 pulley in a cadaveric model u...
متن کاملThyroid surgery with a harmonic scalpel: an experimental study
BACKGROUND The goal of the study was to determinate the safety of the harmonic scalpel, widely used in thyroidectomy, near the recurrent laryngeal nerve (RLN). METHODS The study involved ten pigs of either sex. Twenty RLNs at risk were dissected using the new harmonic scalpel FOCUS. The distances between the nerve and the activated instrument were checked with a millimeter ruler. After dissec...
متن کامل