An in-vitro evaluation of aortic arch vessel perfusion characteristics comparing single versus multiple stream aortic cannulae.

نویسندگان

  • E Joubert-Hübner
  • A Gerdes
  • P Klapproth
  • K Esders
  • J Prosch
  • P Henke
  • G Pfister
  • H H Sievers
چکیده

OBJECTIVE During extracorporeal circulation design and orientation of aortic cannulae tips mainly determine flow pattern in the aortic arch and arch vessels which is the objective of this in vitro study, comparing single versus multiple stream cannulae. METHODS In an aortic arch glass model, jet streams of 21-24 French aortic cannulae which were inserted in the ascending aorta were directed alternatively at the different arch vessels. Flows and pressures in the arch vessels were measured at pump flows of 3-6 l/min. RESULTS With optimal orientation of the jet stream in the aortic arch, no preferential flow in the arch vessels was seen. In the single jet stream aortic cannulae group a significant parallel increase in flow and pressure in the jet streamed arch vessels compared to the non-jet streamed arch vessels occurred (P < 0.05). With the jet stream directed on vessel 2 (left carotid vessel) there was a significant pressure and flow difference comparing the two non-jet streamed vessels with each other (P < 0.03). In the single stream 24 French cannulae the highest vessel pressure of 168 mmHg and an increase in flow of 186 ml/min was measured in the jet streamed left carotid artery at 6 l/min pump flow. The multiple stream cannulae provoked the highest vessel pressure of 106 mmHg in the corresponding jet streamed vessel and an increase in flow of 20 ml/min. CONCLUSION Tip design of aortic cannulae and the orientation of its jet stream are potential sources of remarkable imbalance of arch vessel perfusion especially with single jet stream cannulae. These effects are more pronounced with single jet stream cannulae. These results may have important clinical implications regarding perfusion of arch vessels during extracorporeal circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stridor in a Newborn with Double Aortic Arch-A Case Report

Introduction: Double aortic arch (DAA) is a congenital anomaly of the aortic arch. It is the most common type of complete vascular ring. When it occurs, the connected segment of the aortic arch and its branches encircle the trachea and esophagus, leading to symptoms related to these two structures. Case Report: We present a case of a newborn baby who developed biphasic stridor immediately after...

متن کامل

A Retroesophageal Right Subclavian Artery as the Last Branch of the Aortic Arch- In Vivo Case Report

Three major arteries normally originate from the aortic arch. Variations of the aortic arch branches are observed in some cases. Rare variation of the aortic arch branches is originated from the retroesophageal right subclavian (RRS) artery as the last branch of the aortic arch. Variation of artery is possibly associated with the variation of the recurrent laryngeal nerve. This research p...

متن کامل

A Rare Variation of Right Subclavian Artery Origin from Posterior Surface of Aortic Arch

Purpose: Several variations of aortic arch have been reported yet. In present study another variation of aortic arch was reported. Right subclavian artery arises from posterior surface of the distal end of the aortic arch. Case Report: we present a variation of an aorticarch in which right subclavian artery arisesfrom posterior surface of the distal end of the aortic arch and passing behind eso...

متن کامل

Aortic cannulation.

In heart-lung bypass the arterial blood can be returned to the patient by a variety of methods; these differ in the type of cannula used, the site of insertion, and the technique of insertion. 'Cannulae' have been fashioned from both biological (homograft aorta; Dodrill, Marshall, Nyboer, Hughes, Derbyshire, and Stearns, 1957) and synthetic materials (metal and plastic; Nuniez and Bailey, 1959)...

متن کامل

Newborn aortic arch reconstruction with descending aortic cannulation improves postoperative renal function.

BACKGROUND A clinically driven transition in perfusion technique occurred at Children's Hospital and Medical Center, Omaha, Nebraska, from primarily selective cerebral perfusion bracketed by brief periods of deep hypothermic circulatory arrest to a technique of dual arterial perfusion including innominate artery and descending aortic cannulation (DAC), with continuous mildly hypothermic (>30 °C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 1999