Flow-injection spectrofluorometric determination of trace amounts of formaldehyde in water after derivatization with acetoacetanilide.

نویسندگان

  • Qiong Li
  • Mitsuko Oshima
  • Shoji Motomizu
چکیده

A novel fluorophotometric method for formaldehyde determination in environmental waters was developed: the method does not require any enrichment procedures. A flow-injection analysis method for the spectrofluorometric determination of formaldehyde in waters, which is based on the reaction of formaldehyde with acetoacetanilide and ammonia, is proposed. The proposed method shows a good linearity from 0.50 to 40x10(-7)M, and the limit of detection (LOD) of 3x10(-9)M (0.09 ppb) is achievable. The sample throughput is 15 h(-1). One of the main advantages in the proposed method is that the reaction can be carried out at room temperature without any heating system. The effect of various interferences possibly present in the real water samples was investigated. Most cations and anions, as well as organic compounds, do not interfere with the determination of formaldehyde in environmental water samples. The proposed method is very simple, rapid, less expensive, and highly sensitive, and can be applied to the environmental water samples, such as rain, tap water and river water, at low concentration levels without any enrichment procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Very Low Level of Free Formaldehyde in Liquid Detergents and Cosmetic Products Using Photoluminescence Method

Formaldehyde is commonly used in detergents and cosmetic products as antibacterial agent and preservative. This substance is unfavorable for human health because it is known to be toxic for humans and causes irritation of eyes and skins. The toxicology studies of this compound indicate risk of detergents and cosmetic formulations with a minimum content of 0.05% free formaldehyde. Therefore, det...

متن کامل

Spectrophotometric Determination of Formaldehyde in Seawater Samples after In-situ Derivatization and Dispersive Liquid-Liquid Microextraction

In this paper, a simple dispersive liquid-liquid microextraction for the extraction and pre-concentration of formaldehyde in seawater samples followed with spectrophotometric is proposed. Formaldehyde was derivatized in situ with acetyl acetone in the presence of ammonium acetate in a single step. Then it was collected into a mixture of ethanol (disperser solvent) and chloroform (extracting...

متن کامل

A new spectrofluorometric probe for the determination of trace amounts of CoA in injection, human serum and pig livers.

A new spectrofluorometric method has been developed for the determination of trace amounts of coenzyme A (CoA). Using europium (Eu3+)-tetracycline (TC) complex as a fluorescent probe in the buffer solution of pH 6.80, CoA could remarkably enhance the fluorescence intensity of the Eu3+-TC complex at lambda = 612 nm after adding H(5)IO(6) and the enhanced fluorescence intensity is in proportion t...

متن کامل

Ultra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis

Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...

متن کامل

Sepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114

2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 72 5  شماره 

صفحات  -

تاریخ انتشار 2007