Performance of R410A and R22 Low GWP Alternative Refrigerants at Elevated Ambient Temperatures

نویسندگان

  • Kenneth J. Schultz
  • Kenneth SCHULTZ
چکیده

Growing concerns about the global warming impact of refrigerants used in HVAC&R equipment are driving development and evaluation of alternative refrigerants with lower global warming potentials (GWPs). The Air Conditioning, Heating, and Refrigeration Institute (AHRI) recently coordinated the Low-GWP Alternative Refrigerant Evaluation Program (AREP) in which commercial, university, and government laboratories ran tests of a range of alternative refrigerants in a variety of HVAC&R products. This paper reports the performance of a 4.4 RT (15.5 kW) air-cooled water chiller / heat pump run with a number of lower GWP alternative refrigerants. Tests were first run with a compressor designed for R410A-like pressures. The refrigerants tested include R410A (baseline) and R32, along with blends labeled DR-5, DR-4, L-41a, L-41b, ARM70a, ARM-32a, and HPR1D. The compressor was then replaced with one designed for R22-like pressures. The refrigerants tested include R22 (baseline) along with blends labeled DR-4, DR-7, ARM-32a, L-20, LTR4X, and LTR6A. The blends contain R32, R1234yf, R1234ze(E), R134a, R152a, R125, and R744 (CO2). The results of this project have been reported previously for performance measured at the nominal operating condition of 7.2°C (45°F) leaving chiller water temperature and 35°C (95°F) ambient air temperature (Schultz and Kujak, 2012, 2013a, 2013b; Schultz, 2014). In this paper, performance over an extended range of air temperatures from 24°C to 46°C (75°F to 115°F) is reported and compared to a simple thermodynamic cycle model. The predicted performance benefits of some refrigerants were not observed at elevated air temperatures in the equipment tested. However, none of the alternative refrigerants performed significantly worse than R410A at elevated ambient air temperatures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Performance of a Window Air Conditioner Using Alternative Refrigerants R22 AND R410A

This paper presents the experimental performance analysis of a window air conditioner using two refrigerants R22 and R410A.The effect of the different parameters of performance analysis (refrigeration capacity, COP, compressor power ,pressure ratio ) were investigated for various evaporating temperature and ambient temperature. .The result shows that refrigerant R22 is better than R410A in case...

متن کامل

A Comparison Of An R22 And An R410A Air Conditioner Operating At High Ambient Temperatures

R22 and R410A split air-conditioning systems were tested and compared as outdoor temperature ranged from 27.8 °C (82.0 °F) to 54.4 °F (130 °F). The R410A system tests were extended to 68.3 °C (155.0 °F) ambient temperature with a customized compressor. Capacity and efficiency of both systems decreased linearly with increasing outdoor temperature, but the R410A system performance degraded more t...

متن کامل

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

Concerns about the impact on the environment of the refrigerants used in HVAC&R equipment are driving the development of alternative refrigerants with lower global warming potentials (GWPs). This paper reports the performance of DR-55 (now designated as R452B), DR-5A (now designated as R454B), and R32 in comparison to R410A at the component level from tests run on a 4 RT (14 kW) commercial unit...

متن کامل

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â•fi Summary of Phase I Testing Results

The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) recently completed the first phase of its low global warming potential alternative refrigerants evaluation program (Low-GWP AREP). This industry-wide cooperative research program identified and evaluated promising alternative refrigerants’ performance over the past two years. Thirty-eight low-GWP refrigerants were tested during t...

متن کامل

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

Abstract—In present paper, the performance of various alternative refrigerants is compared to find the substitute of R22, the widely used hydrochlorofluorocarbon refrigerant in developing countries. These include the environmentally friendly hydrofluorocarbon (HFC) refrigerants such as R134A, R410A, R407C and M20. In the present study, a steady state thermodynamic model (includes both first and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014