Prevention of Incisional Hernias with Biological Mesh: A Systematic Review of the Literature

نویسندگان

  • Filip E. Muysoms
  • An Jairam
  • Manuel López-Cano
  • Maciej Śmietański
  • Guido Woeste
  • Iris Kyle-Leinhase
  • Stavros A. Antoniou
  • Ferdinand Köckerling
چکیده

BACKGROUND Prophylactic mesh-augmented reinforcement during closure of abdominal wall incisions has been proposed in patients with increased risk for development of incisional hernias (IHs). As part of the BioMesh consensus project, a systematic literature review has been performed to detect those studies where MAR was performed with a non-permanent absorbable mesh (biological or biosynthetic). METHODS A computerized search was performed within 12 databases (Embase, Medline, Web-of-Science, Scopus, Cochrane, CINAHL, Pubmed publisher, Lilacs, Scielo, ScienceDirect, ProQuest, Google Scholar) with appropriate search terms. Qualitative evaluation was performed using the MINORS score for cohort studies and the Jadad score for randomized clinical trials (RCTs). RESULTS For midline laparotomy incisions and stoma reversal wounds, two RCTs, two case-control studies, and two case series were identified. The studies were very heterogeneous in terms of mesh configuration (cross linked versus non-cross linked), mesh position (intraperitoneal versus retro-muscular versus onlay), surgical indication (gastric bypass versus aortic aneurysm), outcome results (effective versus non-effective). After qualitative assessment, we have to conclude that the level of evidence on the efficacy and safety of biological meshes for prevention of IHs is very low. No comparative studies were found comparing biological mesh with synthetic non-absorbable meshes for the prevention of IHs. CONCLUSION There is no evidence supporting the use of non-permanent absorbable mesh (biological or biosynthetic) for prevention of IHs when closing a laparotomy in high-risk patients or in stoma reversal wounds. There is no evidence that a non-permanent absorbable mesh should be preferred to synthetic non-absorbable mesh, both in clean or clean-contaminated surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HERNIAS, AORTIC SURGERY AND REVIEW OF THE LITERATURE ON INCISIONAL HERNIAS Kile, kirurgija aorte i pregled literature incizijskih hernija

Objectives: To study the relation of incisional hernias after abdominal aortic surgery and to study the recommendations for prevention of incisional hernias in general. Methods: An extensive search in Pub-Med was conducted. We used the following MeSH terms; abdominal aortic aneurysm; incisional hernia; inguinal hernia; incisional hernia and radiology, abdominal wound closure, we also did a “sno...

متن کامل

Chronic Abdominal Pain Secondary to Mesh Erosion Into Ceacum Following Incisional Hernia Repair: A Case Report and Literature Review

Incisional hernias following abdominal operations are a common complication. Mesh is frequently employed in repair of these hernias. Mesh migration is an infrequent occurrence. We present the case of transmural mesh migration from the abdominal wall into the ceacum presenting as chronic abdominal pain. Given the popularity of minimally invasive surgery utilizing polypropylene mesh for incisiona...

متن کامل

Abdominal wall reconstruction with mesh and components separation.

Incisional hernias in the abdominal wall are a by-product of multiple previous laparotomies. Unfortunately, the incidence of incisional hernias has risen, as we have progressed with new surgical techniques in the treatment of abdominal pathologies. Many methods have been attempted in the past to achieve a better and more durable repair, namely using components separation to bring the fascia int...

متن کامل

Chronic abdominal pain secondary to mesh erosion into cecum following incisional hernia repair: a case report and literature review

Incisional hernias following abdominal operations are a common complication. Mesh is frequently employed to repair these hernias. Given the popularity of minimally invasive surgery utilizing polypropylene mesh for incisional hernia repair, related complications such postoperative hematoma and seroma, foreign body reaction, organ injury, infection, mesh rejection, and fistula are being noted. Me...

متن کامل

Use of biologic mesh at ostomy takedown to prevent incisional hernia: A case series

INTRODUCTION Incisional hernias are a relatively common occurrence after ostomy takedown with a incidence of 30-35%. The use of biologic mesh offers a means to bolster the stoma incision site with a lower risk of infection than synthetic mesh. METHODS This study represents a retrospective chart review of six patients who underwent stoma takedown and had biologic mesh placed in the retrorectus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016