Simple chemiluminescence aptasensors based on resonance energy transfer.

نویسندگان

  • Yeqian Jin
  • Wenjing Shi
  • Mengyun Zhou
  • Yifeng Tu
  • Jilin Yan
چکیده

In the present work, two aptamer-based probes and related sensor systems were developed with chemiluminescence signaling. The detection was based on "turning-on" chemiluminescence with switching "off" of the resonance energy transfer after the aptamer's recognition of the target molecule. In this design, a DNA/aptamer duplex linked a chemiluminescence group and a gold nanoparticle together. Only low-intensity chemiluminescence was obtained due to the highly efficient resonance energy transfer. After introducting the target molecule, structure-switching took place with turning off the energy transfer; thus, a restoration and turning on of the chemiluminescence was obtained. The two designs differed in the chemiluminescence groups, since one was a covalently linked luminol molecule, while the other was a conjugated horseradish peroxidase for the catalysis of further chemiluminescence reactions. These schemes provided simple and effective sensing toward a model analyte, adenosine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A WS2 nanosheet based chemiluminescence resonance energy transfer platform for sensing biomolecules.

We developed a WS2 nanosheet based chemiluminescence resonance energy transfer (CRET) platform for sensing biomolecules. This platform exhibits high detection sensitivity and high specificity for target molecules.

متن کامل

Introducing chemiluminescence resonance energy transfer into immunoassay in a microfluidic format for an improved assay sensitivity.

We report on a novel strategy to improve microfluidic immunoassay sensitivity by introducing chemiluminescence resonance energy transfer (CRET) into the immunoreactions. The proposed CRET-based immunoassay for estradiol (E2, as a model analyte) is one of the most sensitive immunoassay with a limit of detection at 3.6 × 10(-11) M E2 in a microfluidic format.

متن کامل

A graphene oxide platform for the assay of biomolecules based on chemiluminescence resonance energy transfer.

The bifunctionality of graphene oxide (GO) that can highly adsorb single-stranded DNA (ssDNA) and effectively quench the emission of organic dyes is reasonably utilized in a chemiluminescence resonance energy transfer (CRET) system, achieving sensitive and selective detection of DNA (H1V1) and protein (thrombin), respectively.

متن کامل

Nanoparticles based on quantum dots and a luminol derivative: implications for in vivo imaging of hydrogen peroxide by chemiluminescence resonance energy transfer.

Overproduction of hydrogen peroxide is involved in the pathogenesis of inflammatory diseases such as cancer and arthritis. To image hydrogen peroxide via chemiluminescence resonance energy transfer in the near-infrared wavelength range, we prepared quantum dots functionalized with a luminol derivative.

متن کامل

Following Glucose Oxidase Activity by Chemiluminescence and Chemiluminescence Resonance Energy Transfer (CRET) Processes Involving Enzyme-DNAzyme Conjugates

A hybrid consisting of glucose oxidase-functionalized with hemin/G-quadruplex units is used for the chemiluminescence detection of glucose. The glucose oxidase-mediated oxidation of glucose yields gluconic acid and H(2)O(2). The latter in the presence of luminol acts as substrate for the hemin/G-quadruplex-catalyzed generation of chemiluminescence. The glucose oxidase/hemin G-quadruplex hybrid ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 2011