In vitro contrast-enhanced ultrasound measurements of capillary microcirculation: comparison between polymer- and phospholipid-shelled microbubbles.

نویسندگان

  • Dmitry Grishenkov
  • Leif Kari
  • Lars-Ke Brodin
  • Torkel B Brismar
  • Gaio Paradossi
چکیده

The focus of contrast-enhanced ultrasound research has developed beyond visualizing the blood pool and its flow to new areas such as perfusion imaging, drug and gene therapy, and targeted imaging. In this work comparison between the application of polymer- and phospholipid-shelled ultrasound contrast agents (UCAs) for characterization of the capillary microcirculation is reported. All experiments are carried out using a microtube as a vessel phantom. The first set of experiments evaluates the optimal concentration level where backscattered signal from microbubbles depends on concentration linearly. For the polymer-shelled UCAs the optimal concentration level is reached at a value of about 2×10(4)MB/ml, whereas for the phospholipid-shelled UCAs the optimal level is found at about 1×10(5)MB/ml. Despite the fact that the polymer shell occupies 30% of the radius of microbubble, compared to 0.2% of the phospholipid-shelled bubble, approximately 5-fold lower concentration of the polymer UCA is needed for investigation compared to phospholipid-shelled analogues. In the second set of experiments, destruction/replenishment method with varied time intervals ranging from 2ms to 3s between destructive and monitoring pulses is employed. The dependence of the peak-to-peak amplitude of backscattered wave versus pulse interval is fitted with an exponential function of the time γ=A(1-exp(-βt)) where A represents capillary volume and the time constant β represents velocity of the flow. Taking into account that backscattered signal is linearly proportional to the microbubble concentration, for both types of the UCAs it is observed that capillary volume is linearly proportional to the concentration of the microbubbles, but the estimation of the flow velocity is not affected by the change of the concentration. Using the single capillary model, for the phospholipid-shelled UCA a delay of about 0.2-0.3s in evaluation of the perfusion characteristics is found while polymer-shelled UCA provide response immediately. The latter at the concentration lower than 3.6×10(5)MB/ml have no statistically significant delay (p<0.01), do not cause any attenuation of the backscattered signal or saturation of the receiving part of the system. In conclusion, these results suggest that the novel polymer-shelled microbubbles have a potential to be used for perfusion evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visualization of multimodal polymer-shelled contrast agents using ultrasound contrast sequences: an experimental study in a tissue mimicking flow phantom

BACKGROUND A multimodal polymer-shelled contrast agent (CA) with target specific potential was recently developed and tested for its acoustic properties in a single element transducer setup. Since the developed polymeric CA has different chemical composition than the commercially available CAs, there is an interest to study its acoustic response when using clinical ultrasound systems. The aim o...

متن کامل

The utilization of ultrasound and microbubbles for therapy in acute coronary syndromes.

Ultrasound has become a useful high resolution imaging modality for examining the cardiac microcirculation. With the use of microbubbles as an ultrasound contrast agent, ultrasound can be utilized to image the microcirculation and detect capillary flow abnormalities in acute ischaemia. A wide range of ultrasound frequencies (including those used for diagnostic transthoracic imaging) have also b...

متن کامل

Toward increased applicability of ultrasound contrast agents

Ultrasound is one of the most widely used modalities in medical imaging because of its high costeffectiveness, wide availability in hospitals, generation of real-time images, and use of nonionizing radiation. However, the image quality can be insufficient in some patients. Introducing a contrast agent (CA), which comprises a suspension of 2–6 μm-sized microbubbles, improves the image quality an...

متن کامل

Endocardial border delineation capability of a novel multimodal polymer-shelled contrast agent

BACKGROUND A novel polymer-shelled contrast agent (CA) with multimodal and target-specific potential was developed recently. To determine its ultrasonic diagnostic features, we evaluated the endocardial border delineation as visualized in a porcine model and the concomitant effect on physiological variables. METHODS Three doses of the novel polymer-shelled CA (1.5 ml, 3 ml, and 5 ml [5 × 10(8...

متن کامل

Assessment of microcirculation by contrast-enhanced ultrasound: a new approach in vascular medicine.

Contrast-enhanced ultrasound (CEUS) has emerged as a valuable imaging modality that complements and enhances standard vascular ultrasound imaging. Ultrasound contrast agents are gas-filled microbubbles that are injected intravenously and serve as intravascular tracers. Based on the properties to enhance and to quantify the macro- and microcirculation down to the capillary perfusion level in dif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasonics

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2011