Skin disinfection and its efficacy before administering injections.

نویسندگان

  • Gemma Gittens
  • Toni Bunnell
چکیده

The need to disinfect a patient's skin before subcutaneous or intramuscular injection is a much debated practice. Guidance on this issue varies between NHS organisations that provide primary and secondary care. However, with patients being increasingly concerned with healthcare-associated infections, a general consensus needs to be reached whereby this practice is either rejected or made mandatory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of the disinfectants and antiseptics used in hospitals

Background: One of the major causes of increasing nosocomial infections is misusing disinfectants and antiseptics in hospitals. The aim of this study was to evaluate the efficacy of disinfectants and antiseptics using in injections and dressing wards, operation rooms and kitchen of Hamedan hospitals. Materials and Methods: In this study 742 samples were collected before and after disinfect...

متن کامل

Skin disinfection and acupuncture.

The need for skin disinfection before insertion of an acupuncture needle is controversial and there is no specific research on this topic. However research and observations on the effect of, and the need for, skin disinfection before injections forms a good analogy of acupuncture. Whilst micro-organisms present on the surface of the skin are accessible to disinfection, those located under the s...

متن کامل

Musculoskeletal ultrasound guided manoeuvres - a security profile.

BACKGROUND In daily rheumatology clinical practice, routine interventional musculoskeletal ultrasound (MSUS) guided maneuvers such as aspiration, intraarticular or periarticular drug injections require efficient cleaning and disinfection methods for both transducer and patient's skin. AIM To study the efficacy of probe and skin disinfection measures after using simple protocols, to identify t...

متن کامل

بررسی فراوانی آلودگی میکروبی دستگاه های بیومیکروسکوپ چشمی Slit-lamp موجود در مرکز چشم پزشکی بیمارستان فرشچیان همدان و ارزیابی ضد عفونی کننده های موجود

Background and Objectives: The aim of this study is the evaluation of bacterial contamination of Slit-lamps in Eye Centers of Farshchian Hospital and assessment of the current disinfectants on isolated bacteria from apparatuses. Methods: In a cross-sectional study, 400 samples were collected from different parts of Slit-lamps (200 samples before and 200 samples after disinfection). The samp...

متن کامل

A comparative study on the efficacy of intralesional injections of Bleomycin and Normal Saline in treatment of recalcitrant common warts on palm and dorsum of hand

Background: Wart is a common skin disease, and 8% of patients referred to dermatologists suffer from warts. Objective: To compare the efficacy of intralesional injections of bleomycin with normal saline in treatment of common resistant warts on palms and dorsum of hands. Patients & Methods: This study was a double blind, randomized, controlled clinical trial on 34 patients with common war...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nursing standard (Royal College of Nursing (Great Britain) : 1987)

دوره 23 39  شماره 

صفحات  -

تاریخ انتشار 2009