Evaluation of multiple implant-bone parameters on stress characteristics in the mandible under traumatic loading conditions.

نویسندگان

  • Hong Guan
  • Rudi van Staden
  • Yew-Chaye Loo
  • Newell Johnson
  • Saso Ivanovski
  • Neil Meredith
چکیده

PURPOSE The inter-relationships between various implant and bone parameters were evaluated for their influence on the von Mises stress distribution within the mandible using the finite element procedure. The maximum compressive stresses in cancellous and cortical bone were compared to the published stress-strain data to determine bone fracturing status when the maximum (traumatic) loading is applied. MATERIALS AND METHODS Parameters considered herein include the implant diameter and length. Also considered are Young's modulus of cancellous bone and that of cortical bone, along with its thickness. The implant-bone system was modeled using two-dimensional plane strain elements, 50% osseointegration between implant and cancellous bone was assumed, and linear relationships were assumed between the stress value and Young's modulus of both cancellous and cortical bone at any specific point within the mandible. RESULTS Implant length was more influential than implant diameter within cancellous bone, whereas implant diameter was more influential in cortical bone. A ranking of all the parameters indicated that the applied masticatory force had a more significant influence on the stress difference, in both cancellous and cortical bone, than all other parameters. Young's modulus of cortical bone and implant length were least influential in cancellous and cortical bone, respectively. Under traumatic loading, cancellous bone fractured for all parameter combinations. When all parameters were set to their average values, the cortical bone did not fracture under traumatic loading. However, it fractured if all the parameters were all set to the minimum values. CONCLUSION Quantitative evaluation and ranking of the major implant and bone parameters will help provide practical guidelines that are useful for the design and testing of dental implants. The study may also be of interest to dental professionals in evaluating possible implant placement options under various clinical scenarios.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

P. Premanand AN EVALUATION OF THE STRESS DISTRIBUTION IN CORTICAL AND CANCELLOUS BONE AROUND A MICROIMPLANT UNDER VARIOUS LOADING CONDITIONS – AN FESA STUDY

Aim: This study is to evaluate the pattern of stress distribution and bone failure around the Absoanchor micro-implant under various loading conditions and various force levels. Materials and Methods: FESA was originally introduced as a numerical form of analysis in aeronautical engineering and has the potential to obtain a computer generated mathematic model of a real object of complicated sha...

متن کامل

مقایسه بیومکانیکی ایمپلنت دندانی تیتانیوم خالص با زیرکونیوم -5/2% نایوبیوم پس از کاشت به روش اجزای محدود

Background and Aims: Improving dental implantation conditions in order to reduce the failure is always desirable for researchers. The aim of this study was to compare two different materials of dental implants from the viewpoint of biomechanical effect after placement and loading in the mandible. Materials and Methods: A 3D model of mandible was designed in the MIMICS 10.01 software. Then,...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Three-Dimensional Finite Elemental Analysis of Bone Stress near an Implant Placed at the Border between Mandible and Fibular Graft in Mandibular Reconstruction

Purpose: The aim of the present study was to use finite elemental analysis (FEA) to evaluate bone stress near an implant placed at the border between the mandible and fibular graft in mandibular reconstruction. Materials and Methods: A fibular model (FM) and transplantation model (TM) were constructed for FEA. In TM, mandible was on the mesial side and the fibular graft was on the distal side. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2010