Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis

نویسندگان

  • Mohammed Hadi Latifi
  • Kunalan Ganthel
  • Shanmugam Rukmanikanthan
  • Azura Mansor
  • Tunku Kamarul
  • Mehmet Bilgen
چکیده

BACKGROUND Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractures in the subtrochancteric region has yet to be explored. Therefore, this comparative study was undertaken to demonstrate the merits of the LP implant in treating the subtrochancteric fracture by comparing its performance limits against those obtained with the more traditional implants; angle blade plate (ABP) and dynamic condylar screw plate (DCSP). MATERIALS AND METHODS Nine standard composite femurs were acquired, divided into three groups and fixed with LP (n = 3), ABP (n = 3) and DCSP (n = 3). The fracture was modeled by a 20 mm gap created at the subtrochanteric region to experimentally study the biomechanical response of each implant under both static and dynamic axial loading paradigms. To confirm the experimental findings and to understand the critical interactions at the boundaries, the synthetic femur/implant systems were numerically analyzed by constructing hierarchical finite element models with nonlinear hyperelastic properties. The predictions from the analyses were then compared against the experimental measurements to demonstrate the validity of each numeric model, and to characterize the internal load distribution in the femur and load bearing properties of each implant. RESULTS The average measurements indicated that the constructs with ABP, DCPS and LP respectively had overall stiffness values of 70.9, 110.2 and 131.4 N/mm, and exhibited reversible deformations of 12.4, 4.9 and 4.1 mm when the applied dynamic load was 400 N and plastic deformations of 11.3, 2.4 and 1.4 mm when the load was 1000 N. The corresponding peak cyclic loads to failure were 1100, 1167 and 1600 N. The errors between the displacements measured experimentally or predicted by the nonlinear hierarchical hyperelastic model were less than 18 %. In the implanted femur heads, the principal stresses were spatially heterogeneous for ABP and DCSP but more homogenous for LP, meaning LP had lower stress concentrations. CONCLUSION When fixed with the LP implant, the synthetic femur model of the subtrochancteric fracture consistently exceeds in the key biomechanical measures of stability and durability. These capabilities suggest increased resistance to fatigue and failure, which are highly desirable features expected of functional implants and hence make the LP implant potentially a viable alternative to the conventional ABP or DCSP in the treatment of subtrochancteric femur fractures for the betterment of clinical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis

The first publication of the work [1] did not present one of the authors' names. Kunalan Ganthel has now been added to the author list. In addition, Habib Sherkat has been added to the Acknowledgements, with thanks for providing help with the use of hyperelastic module of Abaqus Software. Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration...

متن کامل

Mind the gap between the fracture line and the length of the working area: a 2-D finite element analysis using an extramedullary fixation model☆

Objective To determine the ideal working area for a simple transverse fracture line treated with a bridge plate. Methods A 2-D finite element analysis of a hypothetical femur was performed for the quantitative evaluation of a large-fragment titanium alloy locking plate based on the precept of relative stability in a case of a simple transverse diaphyseal fracture. Two simulations (one case of...

متن کامل

Surgical Outcomes of Biologic Fixation for Subtrochanteric Fracture Using Locking Compression Plates

PURPOSE This study aimed to evaluate the surgical outcomes of biologic plating using locking compression plate-distal femur (LCP-DF) in patients with subtrochanteric fracture of the femur. MATERIALS AND METHODS Between January 2010 and December 2013, 28 consecutive patients with subtrochanteric fractures of the femur, treated with biologic fixation using LCP-DF, were enrolled. Preoperative va...

متن کامل

Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures

BACKGROUND When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described impla...

متن کامل

Finite element analysis of locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation

Objective The optimal plate for fixation of tarsometatarsal joint injuries is controversial. The objective of this study was to compare the biomechanical characteristics between a locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation. Method Finite element analysis was used after establishment of a first tarsometatarsal joint fracture-dislocation model. Two im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -