SCIENTIFIC REPORT A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses
نویسندگان
چکیده
Aims: To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). Methods: 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior capsule opening, and degree of posterior capsule opacification were measured using the Scheimpflug anterior segment analysis system (Nidek EAS-1000). Visual acuity and contrast sensitivity were examined. Measurements were performed by masked examiners before and 1 day, 1 week, 1, 3, 6, and 18 months after surgery. Results: There were no significant differences between the two groups (p.0.05, paired t test) in the amount of IOL decentration, IOL tilt, area of anterior capsule opening, degree of posterior capsule opacification, best corrected visual acuity, and contrast sensitivity throughout the 18 month follow up period. Conclusion: The single and three piece acrylic foldable IOLs are equally stable in the eye after surgery.
منابع مشابه
A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.
AIMS To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). METHODS 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior cap...
متن کاملEffect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses.
PURPOSE To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University o...
متن کاملAdhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study.
AIMS To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between th...
متن کاملLate Opacification of Foldable Intraocular Lenses
Objective: To report opacification of hydrophilic acrylic and silicone foldable intraocular lenses (IOL). Designs: Case series. Participants: Five patients with IOL opacification. Results: We report five eyes of five patients with late opacification of the intraocular lens (IOL). Three patients had hydrophilic acrylic (SC60B-OUV-MDR, Inc), two had silicone IOL (Allergan SI30NB). Two out of the ...
متن کاملAnterior Segment Intraocular Lens Edge Profiles of Currently Available Intraocular Lenses and Recent Improvements
We evaluated the microstructure of the edges of currently available foldable intraocular lenses (IOLs). The methodology used assisted an IOL manufacturer (Hoya, Japan) to optimise the edge profile of its lenses. Ten designs of hydrophobic acrylic, six designs of silicone and 24 designs of hydrophilic acrylic IOLs were imaged under scanning electron microscopy (SEM), and the photographs were imp...
متن کامل