Assessment of dead-space ventilation in patients with acute respiratory distress syndrome: a prospective observational study.
نویسندگان
چکیده
BACKGROUND Physiological dead space (VD/VT) represents the fraction of ventilation not participating in gas exchange. In patients with acute respiratory distress syndrome (ARDS), VD/VT has prognostic value and can be used to guide ventilator settings. However, VD/VT is rarely calculated in clinical practice, because its measurement is perceived as challenging. Recently, a novel technique to calculate partial pressure of carbon dioxide in alveolar air (PACO2) using volumetric capnography (VCap) was validated. The purpose of the present study was to evaluate how VCap and other available techniques to measure PACO2 and partial pressure of carbon dioxide in mixed expired air (PeCO2) affect calculated VD/VT. METHODS In a prospective, observational study, 15 post-cardiac surgery patients and 15 patients with ARDS were included. PACO2 was measured using VCap to calculate Bohr dead space or substituted with partial pressure of carbon dioxide in arterial blood (PaCO2) to calculate the Enghoff modification. PeCO2 was measured in expired air using three techniques: Douglas bag (DBag), indirect calorimetry (InCal), and VCap. Subsequently, VD/VT was calculated using four methods: Enghoff-DBag, Enghoff-InCal, Enghoff-VCap, and Bohr-VCap. RESULTS PaCO2 was higher than PACO2, particularly in patients with ARDS (post-cardiac surgery PACO2 = 4.3 ± 0.6 kPa vs. PaCO2 = 5.2 ± 0.5 kPa, P < 0.05; ARDS PACO2 = 3.9 ± 0.8 kPa vs. PaCO2 = 6.9 ± 1.7 kPa, P < 0.05). There was good agreement in PeCO2 calculated with DBag vs. VCap (post-cardiac surgery bias = 0.04 ± 0.19 kPa; ARDS bias = 0.03 ± 0.27 kPa) and relatively low agreement with DBag vs. InCal (post-cardiac surgery bias = -1.17 ± 0.50 kPa; ARDS mean bias = -0.15 ± 0.53 kPa). These differences strongly affected calculated VD/VT. For example, in patients with ARDS, VD/VTcalculated with Enghoff-InCal was much higher than Bohr-VCap (VD/VT Enghoff-InCal = 66 ± 10 % vs. VD/VT Bohr-VCap = 45 ± 7 %; P < 0.05). CONCLUSIONS Different techniques to measure PACO2 and PeCO2 result in clinically relevant mean and individual differences in calculated VD/VT, particularly in patients with ARDS. Volumetric capnography is a promising technique to calculate true Bohr dead space. Our results demonstrate the challenges clinicians face in interpreting an apparently simple measurement such as VD/VT.
منابع مشابه
Comparison of the Heated Humidified High-flow Nasal Cannula with Nasal Continuous Positive Airway Pressure as Primary Respiratory Support for Preterm Neonates: A Prospective Observational Study
Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity in the management of respiratory distress in preterm neonates. However, it is not known whether it takes precedence over the gold standard nasal continuous positive airway pressure (NCPAP) in this age group as a primary mode of non-invasive ventilation (NIV). There is limited evidence ...
متن کاملAlveolar Dead Space Fraction Discriminates Mortality in Pediatric Acute Respiratory Distress Syndrome.
OBJECTIVES Physiologic dead space is associated with mortality in acute respiratory distress syndrome, but its measurement is cumbersome. Alveolar dead space fraction relies on the difference between arterial and end-tidal carbon dioxide (alveolar dead space fraction = (PaCO2 - PetCO2) / PaCO2). We aimed to assess the relationship between alveolar dead space fraction and mortality in a cohort o...
متن کاملAcute Respiratory Distress Syndrome in a Patient With Suspected Influenza: A Case Report
Acute Respiratory Distress Syndrome (ARDS) is a clinical syndrome consisting of tachypnea, refractory hypoxemia, and diffuse opacities on chest radiographs after infection or trauma which ultimately leads to respiratory failure. The principles of treatment are based on patient care in ICU, mechanical ventilation and medical treatments. By using lower plateau, less tidal volume, higher positive ...
متن کاملThe effects of apparatus dead space on P(aCO2) in patients receiving lung-protective ventilation.
BACKGROUND Lung-protective ventilation using tidal volume (V(T)) of 4-6 mL/kg (predicted body weight) reduces mortality (compared with traditional V(T)) in patients with acute respiratory distress syndrome and acute lung injury. Standardized use of lower V(T) can result in respiratory acidosis and has raised new concerns about the appropriate configuration of the ventilator circuit, especially ...
متن کاملEarly application of airway pressure release ventilation may reduce mortality in high-risk trauma patients: a systematic review of observational trauma ARDS literature.
BACKGROUND Adult respiratory distress syndrome is often refractory to treatment and develops after entering the health care system. This suggests an opportunity to prevent this syndrome before it develops. The objective of this study was to demonstrate that early application of airway pressure release ventilation in high-risk trauma patients reduces hospital mortality as compared with similarly...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care
دوره 20 1 شماره
صفحات -
تاریخ انتشار 2016