[Static and dynamic contrast sensitivity of myopic eyes before and after laser in situ keratomileusis].
نویسندگان
چکیده
OBJECTIVE To evaluate the static and dynamic contrast sensitivity changes in myopic patients before and after laser in situ keratomileusis (LASIK). METHODS Seventy-three eyes in 37 patients with myopia (with or without astigmatism) who received LASIK were tested for static and dynamic contrast sensitivities using the METRO VISION MON ELEC I system at 0.7, 1.4, 2.7, 5.5, 11, and 22 cpd and cps prior to LASIK, and at one-, three-, and six-month intervals after LASIK. RESULTS All eyes gained naked visual acuity of more than 0.5 after LASIK. The contrast sensitivity was depressed at all frequencies 1 month after LASIK, as compared to one week prior to LASIK. The depression at 2.7, 5.5, 11 (P < 0.01) and 22 cpd (P < 0.05) was statistically significant for static contrast sensitivity, and also at 5.5 (P < 0.01) and 11 cps (P < 0.05) for dynamic contrast sensitivity. Myopic eyes between 6.25 D and 14.0 D, and astigmatic eyes 2 DC and more, suffered more static and dynamic contrast sensitivity depression than the myopic eyes between 1.25 D and 6.00 D and astigmatic eyes less than 2 DC. Contrast sensitivities were improved and exceeded preoperative levels 3 months after LASIK, and improved even more 6 months after LASIK. All sequences were statistically significant for static contrast sensitivity (P < 0.01), while only 2.7, 5.5, and 11 cps were statistically significant for dynamic contrast sensitivity (P < 0.01). The astigmatic eyes 2 DC and more showed less improvement, even below the preoperative level at 1.4 cps of dynamic contrast sensitivity. CONCLUSIONS While temporary depression of contrast sensitivity for myopic eyes after LASIK was seen, contrast sensitivity soon returned to exceed preoperative levels at 3 months after LASIK, while improving even more 6 months after LASIK.
منابع مشابه
Detection of static cyclotorsion and compensation for dynamic cyclotorsion in laser in situ keratomileusis.
PURPOSE To evaluate the degree of static and dynamic cyclotorsion using a rotational eye tracker in laser in situ keratomileusis (LASIK) to correct myopic astigmatism. SETTING Rothschild Foundation, Paris, France. DESIGN Cohort study. METHODS Laser in situ keratomileusis with active iris registration using a Zyoptix 100 Hz excimer laser with Advanced Control Eyetracking was performed in e...
متن کاملEffect of Previous Myopic Laser In Situ Keratomileusis on Contrast Sensitivity After Diffractive Multifocal Intraocular Lens Implantations
Objective: To evaluate effects of previous myopic laser in-situ keratomileusis (LASIK) on decrease in contrast sensitivity after implantation of diffractive multifocal intraocular lens (MF-IOL). Methods: Retrospective case series included eyes that were implanted diffractive MF-IOLs after myopic LASIK. Contrast sensitivity was measured 1 month postoperatively and the area under log contrast sen...
متن کاملVisual acuity and macular sensitivity in myopic eyes before and after laser in situ keratomileusis.
PURPOSE To evaluate the changes in visual acuity (VA) and in macular sensitivity in myopic eyes subjected to laser in situ keratomileusis (LASIK) refractive surgery. METHODS In 38 myopic eyes, VA by Snellen's table and macular sensitivity by scanning laser ophthalmoscope (SLO) microperimetry were assessed before and after 24 weeks after LASIK surgery. The myopic eyes were divided into three a...
متن کاملVisual Outcomes, Quality of Vision, and Quality of Life of Diffractive Multifocal Intraocular Lens Implantation after Myopic Laser In Situ Keratomileusis: A Prospective, Observational Case Series
Purpose. To report visual performance and quality of life after implantation of a bifocal diffractive multifocal intraocular lens (MIOL) in postmyopic laser in situ keratomileusis (LASIK) patients. Methods. Prospective, observational case series. Patients with prior myopic LASIK who had implantation of Tecnis ZMA00/ZMB00 MIOL (Abbott Medical Optics) at Hong Kong Sanatorium and Hospital were inc...
متن کاملCorneal ectasia after myopic laser in situ keratomileusis: a long-term study
BACKGROUND The purpose of this study was to evaluate the long-term postoperative incidence of and key factors in the genesis of corneal ectasia after myopic laser-assisted in situ keratomileusis (LASIK) in a large number of cases. METHODS A retrospective review of one surgeon's myopic LASIK database was performed. Patients were stratified into two groups based on date of surgery, ie, group 1 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae
دوره 25 5 شماره
صفحات -
تاریخ انتشار 2003