A clinical evaluation of setup errors for a prostate immobilization system
نویسندگان
چکیده
A prostate treatment immobilization system was evaluated with respect to setup errors and efficiency for a specific treatment setup. Prostate patients were treated in the prone position with a rectal catheter using the NOMOS intensity modulated radiotherapy system. Immobilization and setup consisted of a Vac-Loktrade mark bag (MED-TEC, Orange City, IO) fitted within a registration carrier box where patients were aligned to the bag using skin marks along the lower leg. Daily setup errors were analyzed using lateral portal films, registration plates mounted to the carrier box, and the pubic symphasis as a bony reference. Two studies were conducted to evaluate setup technique. In the first study, patient setup required 3-5 minutes for patient positioning and the corresponding superior/inferior errors were found to have a standard deviation of 3.5 mm. In the second study, the technique standards were reduced to allow for faster setup times and, consequently, larger errors; setup times were 1-2 minutes and the mean and standard deviation errors were approximately 2 and 5 mm, respectively.
منابع مشابه
Evaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System
Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: ...
متن کاملImage-guided prostate radiotherapy: analysis of inter- fractional setup errors
Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...
متن کاملEvaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on‐board imaging†
The purpose of this study was to evaluate setup accuracy and quantify random and systematic errors of the BrainLAB stereotactic immobilization mask and localization system using kV on-board imaging. Nine patients were simulated and set up with the BrainLAB stereotactic head immobilization mask and localizer to be treated for brain lesions using single and hypofractions. Orthogonal pairs of proj...
متن کاملUtilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
متن کاملAssessment of setup uncertainties for various tumor sites when using daily CBCT for more than 2200 VMAT treatments
The aim of this study was assess the patient setup errors for various tumor sites based on clinical data from a sufficient number of treatments with volumetric-modulated arc therapy (VMAT) using daily pretreatment CBCT imaging guidance. In addition, we calculated and compared the planning target volume (PTV) margins for all disease sites based on an analysis of specific systematic and random er...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1 شماره
صفحات -
تاریخ انتشار 2000