Effect of positive pressure on venous return in volume-loaded cardiac surgical patients.
نویسندگان
چکیده
The hemodynamic effects of increases in airway pressure (Paw) are related in part to Paw-induced increases in right atrial pressure (Pra), the downstream pressure for venous return, thus decreasing the pressure gradient for venous return. However, numerous animal and clinical studies have shown that venous return is often sustained during ventilation with positive end-expiratory pressure (PEEP). Potentially, PEEP-induced diaphragmatic descent increases abdominal pressure (Pabd). We hypothesized that an increase in Paw induced by PEEP would minimally alter venous return because the associated increase in Pra would be partially offset by a concomitant increase in Pabd. Thus we studied the acute effects of graded increases of Paw on Pra, Pabd, and cardiac output by application of inspiratory-hold maneuvers in sedated and paralyzed humans. Forty-two patients were studied in the intensive care unit after coronary artery bypass surgery during hemodynamically stable, fluid-resuscitated conditions. Paw was progressively increased in steps of 2 to 4 cmH(2)O from 0 to 20 cmH(2)O in sequential 25-s inspiratory-hold maneuvers. Right ventricular (RV) cardiac output (CO(td)) and RV ejection fraction (EF(rv)) were measured at 5 s into the inspiratory-hold maneuver by the thermodilution technique. RV end-diastolic volume and stroke volume were calculated from EF(rv) and heart rate data, and Pra was measured from the pulmonary artery catheter. Pabd was estimated as bladder pressure. We found that, although increasing Paw progressively increased Pra, neither CO(td) nor RV end-diastolic volume changed. The ratio of change (Delta) in Paw to Delta Pra was 0.32 +/- 0.20. The ratio of Delta Pra to Delta CO(td) was 0.05 +/- 00.15 l x min(-1) x mmHg(-1). However, Pabd increased such that the ratio of Delta Pra to Delta Pabd was 0.73 +/- 0.36, meaning that most of the increase in Pra was reflected in increases in Pabd. We conclude that, in hemodynamically stable fluid-resuscitated postoperative surgical patients, inspiratory-hold maneuvers with increases in Paw of up to 20 cmH(2)O have minimal effects on cardiac output, primarily because of an in-phase-associated pressurization of the abdominal compartment associated with compression of the liver and squeezing of the lungs.
منابع مشابه
Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery
Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...
متن کاملThe effect of vascular volume on positive end-expiratory pressure-induced cardiac output depression and wedge-left atrial pressure discrepancy.
Positive end-expiratory pressure (PEEP) is effective in improving arterial oxygenation and decreasing intrapulmonary shunt in patients with the adult respiratory distress syndrome [9, 121. PEEP can also cause a significant reduction in cardiac output [6, 8, 13, 15]anddecreaseinoxygendelivery[12]. The decrease in cardiac output may be due to impaired venous return [ 1, 7, 141, pulmonary vascular...
متن کاملCardiac output response to norepinephrine in postoperative cardiac surgery patients: interpretation with venous return and cardiac function curves.
OBJECTIVE We studied the variable effects of norepinephrine infusion on cardiac output in postoperative cardiac surgical patients in whom norepinephrine increased mean arterial pressure. We hypothesized that the directional change in cardiac output would be determined by baseline cardiac function, as quantified by stroke volume variation, and the subsequent changes in mean systemic filling pres...
متن کاملInfluence of positive airway pressure on the pressure gradient for venous return in humans.
To study the effect of positive airway pressure (Paw) on the pressure gradient for venous return [the difference between mean systemic filling pressure (Pms) and right atrial pressure (Pra)], we investigated 10 patients during general anesthesia for implantation of defibrillator devices. Paw was varied under apnea from 0 to 15 cmH(2)O, which increased Pra from 7.3 +/- 3.1 to 10.0 +/- 2.3 mmHg a...
متن کاملStaying Current Venous return and clinical hemodynamics: how the body works during acute hemorrhage
Shen T, Baker K. Venous return and clinical hemodynamics: how the body works during acute hemorrhage. Adv Physiol Educ 39: 267–271, 2015; doi:10.1152/advan.00050.2015.—Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to ena...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 92 3 شماره
صفحات -
تاریخ انتشار 2002