The Relationship Between Resonance Frequency Analysis (RFA) and Insertion Torque of Dental Implants: an in Vitro Study

نویسندگان

  • Javier Gil
  • Carmen Maria Díaz-Castro
  • José Vicente Ríos-Santos
  • Pedro Lázaro
چکیده

Purpose: The aims of the present study are to correlate the ISQ values, registered by the Osstell ISQ system, with the insertion torque during the placement of the implant, and to assess the influence of the thread initiator on the ISQ values and on the insertion torque. Materials and methods: 140 rough surface implants screw-shaped implants, placed in 10 bovine ribs, were assigned to Group A (using the thread initiator before the insertion of the implant) or Group B (thread initiator was not used). The implants were implantedusing a manual torque wrench so insertion torque was registered. Once the implants were in place, primary stability was measured by means of RFA with the Osstell ISQ. Results: When the thread initiator was used (group A), the mean insertion torque was 24,36 ± 14,88 N and when the thread initiator was not used (group B) the mean insertion torque was 35,30 ± 10,51N. The mean ISQ of the thread initiator group was 69,14 ± 8,39 and of the non thread initiator group was 72,17 ± 5,76. Pearson’s correlation coefficient was 0,587 (p<0,05) for group A and 0,193 (p<0,11) for group B. Conclusions: It seems that the fact of using or not the thread initiator have no influence in the ISQ values. However, the IT decreased when the thread initiator is employed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study.

This in vitro investigation was conducted to study the relationship between resonance frequency analysis (RFA) and lateral displacement measurements of dental implants. A total of 30 implant sites were prepared in nine fresh bovine bone specimens. The bone density around each preparation was determined by using cone beam computerized tomography (CBCT) and imaging software. Dental implants were ...

متن کامل

Determination of primary stability: a comparison of the surgeon's perception and objective measurements.

PURPOSE To evaluate the difference between the dental surgeon's perception of implant stability and the actual insertion torque and actual values obtained through resonance frequency analysis (RFA) during implant insertion surgery. MATERIALS AND METHODS One hundred fifty-two patients who needed one or more dental implants were selected. A total of 514 Xive implants was inserted. For all 514 i...

متن کامل

Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.

BACKGROUND Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES The aims of this study were to determine the initial stability of implants placed into fresh extraction...

متن کامل

Influence of bone density on implant stability parameters and implant success: a retrospective clinical study

BACKGROUND The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success. METHODS A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient sit...

متن کامل

Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.

BACKGROUND Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. PATIENTS AND METHODS Seventy patients with complete mandibular edentulism underwent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016