On the use of an optoacoustic and laser ultrasonic imaging system for assessing peripheral intravenous access

نویسندگان

  • A.S. Bychkov
  • V.P. Zarubin
  • A.A. Karabutov
  • V.A. Simonova
  • E.B. Cherepetskaya
چکیده

We describe a universal system for research in combined real-time optoacoustic (OA) and laser-ultrasonic (LU) imaging. The results of its testing on the task of needle insertion into the blood vessel model diagnostics are presented. In OA mode, where laser light is absorbed directly in the sample, the contents of blood vessel model is clearly visible. In LU mode, where the short ultrasonic probe pulse scattered on the sample is detected, the needle is clearly visible. The developed solution combining OA and LU imaging modalities due to the common detection system allowed real-time diagnostics of the position of medical needles (0.63 mm and 0.7 mm in diameter) inside blood vessel models (1.6 mm and 2.4 mm in diameter). Frame rate was 10 Hz. High longitudinal spatial resolution of the system - 0.1 mm - allows distinguishing the two walls of the vessel model and the position of the needle inside.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optoacoustic imaging using fiber-optic interferometric sensors.

An interferometric sensor based on nonmetallic silica optical fiber is presented as an ultrasonic wideband transducer for optoacoustic imaging applications. We have characterized the sensitivity of the optical fiber sensor by detecting optoacoustic signals from an optically absorbing object embedded in a tissue-mimicking phantom and have compared the signals recorded with those detected from th...

متن کامل

Three-dimensional optoacoustic tomography using a conventional ultrasound linear detector array: whole-body tomographic system for small animals.

PURPOSE Optoacoustic imaging relies on the detection of ultrasonic waves induced by laser pulse excitations to map optical absorption in biological tissue. A tomographic geometry employing a conventional ultrasound linear detector array for volumetric optoacoustic imaging is reported. The geometry is based on a translate-rotate scanning motion of the detector array, and capitalizes on the geome...

متن کامل

Fast scanning coaxial optoacoustic microscopy

The hybrid nature of optoacoustic imaging might impose limitations on concurrent placement of optical and ultrasonic detection components, especially in high resolution microscopic applications that require dense arrangements and miniaturization of components. This hinders optimal deployment of the optical excitation and ultrasonic detection paths, leading to reduction of imaging speed and spat...

متن کامل

Three-Dimensional Optoacoustic Tomography: preclinical research and clinical applications

ID: 17274 Title: Ultrasound Symposium Three-Dimensional Optoacoustic Tomography: preclinical research and clinical applications Alexander A. Oraevsky 1,2 1 TomoWave Laboratories, Houston, Texas, USA 2 Biomedical Engineering Department, University of Houston, Houston, Texas, USA Contact e-mail: [email protected] Abstract We developed a 3D optoacoustic tomography (OAT) system* combining advantages...

متن کامل

Melanin-Based Contrast Agents for Biomedical Optoacoustic Imaging and Theranostic Applications

Optoacoustic imaging emerged in early 1990s as a new biomedical imaging technology that generates images by illuminating tissues with short laser pulses and detecting resulting ultrasound waves. This technique takes advantage of the spectroscopic approach to molecular imaging, and delivers high-resolution images in the depth of tissue. Resolution of the optoacoustic imaging is scalable, so that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017