ICSH recommendations for the measurement of haemoglobin F.

نویسندگان

  • A D Stephens
  • M Angastiniotis
  • E Baysal
  • V Chan
  • B Davis
  • S Fucharoen
  • P C Giordano
  • J D Hoyer
  • A Mosca
  • B Wild
چکیده

Measurement of the Haemoglobin F in red cell haemolysates is important in the diagnosis of δβ thalassaemia, hereditary persistence of fetal haemoglobin (HPFH) and in the diagnosis and management of sickle cell disease. The distribution of Hb F in red cells is useful in the diagnosis of HPFH and in the assessment of feto-maternal haemorrhage. The methods of quantifying Hb F are described together with pitfalls in undertaking these laboratory tests with particular emphasis on automated high-performance liquid chromatography and capillary electrophoresis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HemoCue haemoglobin systems--a clarification.

The preferred method to verify the accuracy of a haemoglobinometer is the International Committee for Standardization in Haematology (ICSH) reference measurement of haemoglobin as haemiglobincyanide in whole blood, using a spectrophotometer which has been calibrated directly by the WHO/ICSH primary international reference standard or by means of a commercial standard that has been manufactured ...

متن کامل

ICSH recommendations for measurement of erythrocyte sedimentation rate. International Council for Standardization in Haematology (Expert Panel on Blood Rheology)

The Expert Panel on Blood Rheology of the International Council for Standardization in Haematology (ICSH) has prepared new recommendations for measurement of the erythrocyte sedimentation rate (ESR) under the following categories: 1. ICSH reference method-ICSH now recognises, as its reference method for the ESR, the sedimentation of EDTA-anticoagulated but undiluted blood in traditional Westerg...

متن کامل

ICSH recommendations for the measurement of haemoglobin A2.

Although DNA analysis is needed for characterization of the mutations that cause β-thalassaemia, measurement of the Hb A(2) is essential for the routine identification of people who are carriers of β-thalassaemia. The methods of quantitating Hb A(2) are described together with pitfalls in undertaking these laboratory tests with particular emphasis on automated high-performance liquid chromato...

متن کامل

Recommendations for measurement of serum iron in human blood.

The following method has been approved by the International Committee for Standardization in Haematology (ICSH) Board for publication as an ICSH standard (EP7/1978).

متن کامل

Recommendation for standardization of haematology reporting units used in the extended blood count.

INTRODUCTION It is desirable in the interest of patient safety that the reporting of laboratory results should be standardized where no valid reason for diversity exists. This study considers the reporting units used for the extended blood cell count and makes a new ICSH recommendation to encourage standardization worldwide. METHODS This work is based on a literature review that included the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of laboratory hematology

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2012