Slow bolus injection of ribose in the identification of thallium-201 redistribution following combined adenosine/dynamic exercise stress.

نویسندگان

  • M G Gunning
  • G Clunie
  • J Bradley
  • N K Gupta
  • J B Bomanji
  • P J Ell
چکیده

AIM A simple stress/redistribution thallium-201 myocardial perfusion imaging protocol may underestimate the degree of thallium redistribution in a defect identified on the stress images. We sought to investigate whether a slow-bolus injection of D-ribose improves the identification of thallium redistribution following combined adenosine/dynamic exercise stress. MATERIALS AND METHODS Fifteen patients (10 males, five female, median age 63 years, range 50-75) were enrolled in the study. All underwent two successive adenosine plus exercise myocardial perfusion scintigraphy protocols 7-14 days apart. Adenosine was infused at 140 micrograms.kg-1.min-1 coupled with 25 W ergometer pedalling for 6 min with 74 Mbq of thallium-201 being injected at 4 min. Immediately following the stress image acquisition, patients received the one of either 60 mg.kg-1 of D-ribose or normal saline, injected over 5 min. Redistribution images were acquired after 4 h. The identical stress procedure was conducted in the crossover arm of the study, and patients received the alternative test article. SPECT images were visually analysed and scored in a nine segment model by two blinded observers. In addition, circumferential profile analysis was conducted. RESULTS By visual interpretation 25 segments displayed redistribution of the ribose, but not in the saline study, 14 reversible segments were seen on the saline study alone and 18 were seen on both studies (P = ns). In six patients ribose identified a greater number of redistributing segments and in a further six patients saline identified more reversible segments. Comparison of mean values of defect extent severity and percentage reversibility scores generated from the circumferential profile analysis showed no significant difference between the two arms of the study. CONCLUSION A 5 min bolus injection of D-ribose following combined adenosine/dynamic exercise stress confers little benefit on the identification of redistribution of thallium-201. These results differ from those of previous studies which showed that a 30 min infusion of D-ribose following treadmill exercise significantly enhanced thallium redistribution. The duration of the ribose infusion is likely to be an important factor influencing the effect brought to bear on the redistribution of the tracer, and should be run over 30 min, or longer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Thallium-201 for assessment of myocardial viability: quantitative comparison of 24-hour redistribution imaging with imaging after reinjection at rest.

Redistribution thallium-201 imaging 2 to 4 h after exercise may be incomplete and therefore may be inadequate to fully assess myocardial variability. Late redistribution imaging 24 h after exercise has been proposed to overcome this limitation of thallium stress imaging. However, because of poor count density the image quality on these studies is often suboptimal. In the present study the diagn...

متن کامل

Dipyridamole combined with exercise for thallium-201 myocardial imaging.

A new stress test for thallium-201 myocardial imaging in which pharmacological coronary vasodilatation with dipyridamole is combined with dynamic exercise is described. In 38 patients with coronary artery disease the sensitivity, total number of defects, degree of redistribution, and visual quality of thallium-201 imaging were greater after dipyridamole with exercise testing than after exercise...

متن کامل

Blood flow redistribution during exercise contributes to exercise tolerance in patients with chronic heart failure.

BACKGROUND It is widely known that blood flow redistribution is impaired in patients with chronic heart failure (CHF). However, the relationship between exercise tolerance and the degree of blood flow redistribution is not fully understood. Whole-body thallium-201 chloride ((201)Tl) scintigraphy can estimate blood flow distribution. This study will evaluate the relationship between exercise tol...

متن کامل

Adenosine thallium-201 is superior to exercise thallium-201 for detecting coronary artery disease in patients with left bundle branch block.

OBJECTIVES We sought to assess the comparative diagnostic accuracy of adenosine versus exercise in conjunction with thallium-201 scintigraphy for the detection and localization of coronary artery disease in patients with left bundle branch block on the rest electrocardiogram (ECG). BACKGROUND Patients with left bundle branch block on the rest ECG frequently have artifactual reversible septal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 17 9  شماره 

صفحات  -

تاریخ انتشار 1996