Right ventricular outflow tract reconstruction with bicuspid valved polytetrafluoroethylene conduit.

نویسندگان

  • Masahiro Yoshida
  • Peter D Wearden
  • Onur Dur
  • Kerem Pekkan
  • Victor O Morell
چکیده

BACKGROUND In general, all conduits available for right ventricular outflow tract (RVOT) reconstruction eventually become stenotic or insufficient. Owing to the lack of an ideal conduit and with the hope of reducing the incidence of reoperations, we have developed and utilized a bicuspid valved polytetrafluoroethylene (PTFE) conduit for the reconstruction of the RVOT. The purpose of this study was to review our early experience with this conduit. METHODS From October 2008 to September 2009, we have implanted bicuspid valved PTFE conduits in 18 patients with a median age of 1.7 years (range 6 days to 16 years). Their diagnoses include tetralogy of Fallot with pulmonary atresia in 8, truncus arteriosus in 6, congenital aortic stenosis in 2, transposition of great arteries in 1, and interrupted aortic arch with a ventricular septal defect in 1. In 16 patients, a complete biventricular repair was performed. In another 2 cases, the conduit was used for palliative RVOT reconstruction. The conduit sizes varied from 10 mm to 24 mm in diameter. Three-dimensional flow fields obtained from computational fluid dynamics studies were utilized in the conduit design process. RESULTS There was no surgical mortality or reinterventions associated with the PTFE conduit placement in our series. At the time of discharge, none of the patients had any echocardiographic findings consistent with significant conduit stenosis or insufficiency. During the follow-up period of 6.2 ± 3.9 months, all patients were alive and only 3 had more than mild pulmonary insufficiency. CONCLUSIONS Our bicuspid valved PTFE conduit has an acceptable early performance, with a low incidence of valve insufficiency and no conduit stenosis. Certainly, longer follow-up is necessary to fully assess its long-term benefits.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of right ventricular outflow tract reconstruction with bicuspid valved polytetrafluoroethylene conduit.

Conduits available for right ventricular outflow tract (RVOT) reconstruction eventually become stenotic and/or insufficient due to calcification. In order to reduce the incidence of reoperations we have developed and used a bicuspid valved polytetrafluoroethylene (PTFE) conduit for the RVOT reconstruction. The purpose of this study is to investigate the hemodynamic performance of the new design...

متن کامل

Modified Ross procedure using a conduit with a synthetic valve.

OBJECTIVE In the Ross procedure, a homograft conduit is commonly used in place of an autotransplanted pulmonary valve. Homograft availability may be a problem and has resulted in a search for alternatives. We performed a modified Ross procedure for right ventricular outflow tract reconstruction with a synthetic valved conduit as an alternative to homograft. Our early results of valvular and rig...

متن کامل

Biventricular repair of pulmonary atresia with intact ventricular septum and severely hypoplastic right ventricle: a case report of a minimum intervention surgical approach

BACKGROUND In patients who have pulmonary atresia with an intact ventricular septum and severe right ventricular hypoplasia, biventricular repair is considered to be impossible and multiple interventions are generally required for definitive repair. CASE PRESENTATION An initial palliative procedure was performed in a 1-month-old boy to promote right ventricular development by pulmonary valvec...

متن کامل

Fresh Pericardial Valved Conduit for Reconstruction of Right Ventricular Outflow Tract in Tetralogy of Fallot with Pulmonary Stenosis or Pulmonary Atresia—Early Results

Objective: To study early results of hand made fresh (autologous/homologous) pericardial valved conduit in achieving right ventricle to pulmonary artery continuity. Method: Between November 2014 and September 2015, 19 cases, with diagnosis of Tetralogy of Fallot with Pulmonary stenosis (PS) or Pulmonary atresia (PA) underwent intracardiac repair and Right Ventricular Outflow Tract (RVOT) recons...

متن کامل

MRSA endocarditis of bovine Contegra valved conduit: a case report

BACKGROUND Different techniques are used for the right ventricular outflow tract reconstruction, including homo- or porcine xenografts, which have several limitations. Contegra, a bovine jugular vein graft, is an interesting alternative to overcome these limitations. It consists of a bovine jugular vein with a naturally integrated valve in it. Isolated pulmonary valve endocarditis is extremely ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 91 4  شماره 

صفحات  -