Large matrix acquisition of a chemically fixed human embryo for construction of a 3D anatomical database

نویسندگان

  • Yosuke Otake
  • Takuma Yamada
  • Katsumi Kose
  • Tomoyuki Haishi
  • Shigehito Yamada
چکیده

INTRODUCTION Kyoto University has a large collection of chemically fixed human embryos (~50,000) collected since 1961 [1]. To construct their 3D anatomical database, 3D MR microscopic images of about 1,200 chemically fixed human embryos from Carnegie Stage (CS) 13 (28-32days) to 23 (56-60 days) were acquired with a 128×128×256 image matrix in a 2.35 T magnetic field [2]. In 2005, 3D MR images of human embryos from CS16 to 23 were acquired with a 256×256×512 image matrix in a 9.4 T magnetic field using saddle shaped RF coils [3]. For a feasibility study of the forthcoming project, we acquired 3D MR microscopic images of a CS22 (54-58 days) human embryo using a 512×512×1024 image matrix (30 μm isotropic resolution) in a 4.7 T magnetic field using a solenoid coil. MATERIALS AND METHODS A CS22 chemically fixed human embryo was inserted into an NMR sample tube (12 mm OD, 10.5 mm ID) filled with preservation fluid to avoid sample motion and susceptibility artifacts (Fig.1). The specimen was inserted into a 4 turn solenoid coil (12.5 mm ID, 25 mm in length) fixed in a gradient coil probe with a planar gradient coil set designed by the target field method and the genetic algorithm. The gradient coil probe was inserted into a 4.74 T vertical bore superconducting magnet (88.3 mm ID). MR images were acquired with a PC (Corei7, 16 GB memory) -based digital MRI system running under the 64-bit Windows 7 operating system utilizing a PC pulse programmer [4]. The pulse sequences were 3D gradient-echo and spin-echo sequences (FOV: (15.36mm)×30.72mm, image matrix: 32~512×512×1024, TR=200ms, TE=6~20ms). RESULTS Figure 2 shows central cross-sections acquired with the 3D gradient-echo and spin-echo pulse sequences using a 32×512×1024 image matrix (each acquisition time ~ 55 minutes). Table 1 shows signal to noise ratio in the central nerve system and the liver. This table shows that T2 of the water mobile protons contained in the fixed specimen was ~ 10 ms. Figure 3 shows mid-sagittal and axial cross-sections acquired with the 512×512×1024 matrix using the 3D gradient echo sequence (TR/TE=200ms/6ms, NEX=1, image acquisition time ~ 14.6 hours). The size of the raw data was 2 GB and the image reconstruction time was less than 30 seconds using the PC. Although some artifacts are seen around the right-hand side of the FOV, the anatomical structures of the embryo are clearly acquired. Figure 4 shows average power of the MRI signal plotted against the wavenumber in the k-space for the 3D image data. This graph suggests that although the noise floor was around -70 dBr, high spatial frequency components of the MRI signal were properly acquired up to ~(30 μm) ~ 30000m [5]. DISCUSSION For construction of the 3D anatomical database of the human embryos, the matrix size, the spatial resolution, and the measurement time are essential. Our experimental results demonstrate that the 512×512×1024 image acquisition, the 30 μm isotropic resolution, and the image acquisition time less than 24 hours were feasible in our 4.7 T digital MRI system. If we use a higher magnetic field (e.g. 9.4 T) together with a solenoid coil, much higher spatial resolution (~20 μm) will be achieved using the same matrix size. In conclusion, the 512×512×1024 image acquisition for chemically fixed human embryos of various developmental stages is feasible with spatial resolutions between 20 and 30 μm at high magnetic fields. REFERENCES 1. Nishimura H et al, Teratology 1968;1:281-290. 2. Matsuda Y, et al. Magn Reson Med Sci 2007;6:139-146. 3. Otake Y, et al, 14th ISMRM Proc, Seattle, 2006, p2017. 4. Hashimoto S, et al, Rev. Sci. Instrum. 83, 053702 (2012). 5. Watts R, Magn Reson Med 2002;48:550-554.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance microscopy of chemically fixed human embryos at high spatial resolution.

We acquired magnetic resonance (MR) microscopic images of chemically fixed human embryos of Carnegie stages 16 to 22 with a large image matrix (256 × 256 × 512) using an MR microscope that we developed with a 9.4-tesla vertical wide-bore superconducting magnet and a dual-channel receiver system to extend the dynamic range of the MR signal. The images showed clear anatomical structures at spatia...

متن کامل

Effect of Two Polarized Culture System Prepared From Human Female Genital Tract on Mouse Embryo Development

Purpose: To compare effects of polarized epithelial monolayer prepared from human oviduct and uterus on mouse one and two-cell embryo development. Materials and Methods: Human oviduct and endometrial tissue was obtained from patients who had undergone total hysterectomy. The epithelial cells were isolated from tissue and cultured on extracellular matrix (ECM) Gel coated Millipore filter insert...

متن کامل

αvβ3 Integrin Express on Mid-luteal Human Endometrium: An Immunogold and Immunofluorescent Staining Study

Introduction: The implantation is a complex procedure that involves many molecules. One of these molecules is integrin specially &alphav&beta3 which serves as receptor for components of extra cellular matrix to act as bridging molecules between the blastocyst and the endometrial surface during the implantation process. By blocking &alphav&beta3 interactions, the implantation can be impaired. ...

متن کامل

I-42: Advanced Ultrasonic Techniques in The Assessment of Early Human Development

Background: To evaluate the role of 3D, 4D and color Doppler ultrasound (US) in the assessment of early human development. Materials and Methods: 380 women with uncomplicated early pregnancy between 5 and 14 weeks were evaluated by 3D, 4D and color Doppler US. Results: Regression analysis revealed exponential rise of the gestational sac volume with gestational age throughout the first trimester...

متن کامل

I-43: Scientific and Religious Controversies on The Beginning of Human Life- What Does 3D/4D Sonography Offer?

One of the most controversial topics in modern bioethics, science, and philosophy is the beginning of individual human life. In the seemingly endless debate, strongly stimulated by recent technologic advances in human reproduction, a synthesis between scientific data and hypothesis, philosophical thought, and issues of humanities has become a necessity to deal with ethical, juridical, and socia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013