Safety of cornea and iris in ocular surgery with 355-nm lasers.

نویسندگان

  • Jenny Wang
  • Jae Lim Chung
  • Georg Schuele
  • Alexander Vankov
  • Roopa Dalal
  • Michael Wiltberger
  • Daniel Palanker
چکیده

A recent study showed that 355-nm nanosecond lasers cut cornea with similar precision to infrared femtosecond lasers. However, use of ultraviolet wavelength requires precise assessment of ocular safety to determine the range of possible ophthalmic applications. In this study, the 355-nm nanosecond laser was evaluated for corneal and iris damage in rabbit, porcine, and human donor eyes as determined by minimum visible lesion (MVL) observation, live/dead staining of the endothelium, and apoptosis assay. Single-pulse damage to the iris was evaluated on porcine eyes using live/dead staining. In live rabbits, the cumulative median effective dose (ED50) for corneal damage was 231 J/cm2, as seen by lesion observation. Appearance of endothelial damage in live/dead staining or apoptosis occurred at higher radiant exposure of 287 J/cm2. On enucleated rabbit and porcine corneas, ED50 was 87 and 52 J/cm2, respectively, by MVL, and 241 and 160 J/cm2 for endothelial damage. In human eyes, ED50 for MVL was 110 J/cm2 and endothelial damage at 453 J/cm2. Single-pulse iris damage occurred at ED 50 of 208 mJ/cm2. These values determine the energy permitted for surgical patterns and can guide development of ophthalmic laser systems. Lower damage threshold in corneas of enucleated eyes versus live rabbits is noted for future safety evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Marfan Syndrome in an Iranian Family: A Case Series

Marfan syndrome (MFS) is a genetic disorder which is inherited by autosomal dominant traits. In MFS, lens displacement and cardiovascular involvement are important causes of morbidity and mortality in the clinical course of the disease. In this case study, the ocular involvement in a family with severe penetration of MFS is reported. Twelve members of a family (father, two daughters, three sons...

متن کامل

Design of the [SiO2/ZrO2] photonic crystal filter for application in 350-nm laser safety glasses

In this paper, a one-dimensional photonic crystal filter based on the [SiO2/ZrO2] bilayer have been designed for application in safety glasses for working in 350-nm wavelength. High power lasers with low wavelength e.g. 350-nm have very high power which can cause serious damage to the operator’s eyes. In this paper using the transfer matrix method and theoretical calculation in MATLAB software ...

متن کامل

Spontaneous malignant glaucoma in a longstanding hypotonous eye.

A 38-year-old man with longstanding low intraocular pressure (IOP) in his right aphakic eye presented with severe pain and high IOP (35 mm Hg). On examination, visual acuity was light perception. The central and peripheral portions of the iris were directly opposed to the posterior corneal surface and synechial closure of the pupil margin. B-scan ultrasonography showed posterior vitreous detach...

متن کامل

Laser eye surgery for refractive errors.

Several laser and non-laser refractive surgical procedures have been used to modify the shape of the cornea and correct myopia, hyperopia, astigmatism, and presbyopia. Introduction of the excimer laser to reshape the cornea has resulted in remarkable developments in the correction of these refractive errors. Combined with other advanced ophthalmological instruments, laser refractive eye surgery...

متن کامل

Ocular injuries related to air bag inflation.

BACKGROUND AND OBJECTIVES The effectiveness of air bags as a safety device in decreasing fatalities and reducing morbidity in frontal impact motor vehicle accidents has been well established. However, case reports have surfaced documenting ocular injuries related to air bag inflation. The purpose of this study was to identify and analyze ocular injuries sustained during air bag inflation. PAT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 2015