Importance of a distal centralizer in experimental malpositioning of cemented stems. A biomechanical study on human femora

نویسندگان

  • Andreas Kusserow
  • Andreas Ficklscherer
  • Peter Cornelius Kreuz
  • Susanne Finze
  • Wolfram Mittelmeier
  • Volkmar Jansson
  • Stefan Milz
  • Bernd Wegener
چکیده

INTRODUCTION Femoral centralizers in total hip arthroplasty (THA) are designed to improve the neutral implant position and ensure a homogeneous cement mantle without implant-bone impingement. To date there are no data about the cement mantle configuration and implant position after malinsertion, as seen in mini-open approaches or adipose patients with a limited view. The present biomechanical study was performed to investigate whether a distal centralizer may correct and optimize the position of a malinserted femoral stem. MATERIAL AND METHODS Thirteen MS 30 stems with and without a distal centralizer each were implanted in paired fresh human femora. Malinsertion was performed using a 3D guiding device with 10° deviation to the femoral axis in the sagittal plane. The thickness of the cement mantle was measured on the anterior, posterior, medial and lateral side of the implanted stem at a distance of 1 cm each. For each side data were taken at 13 points. RESULTS Digital evaluation of the cement mantle thickness revealed compareable values in frontal plane when a centralizer was used (p > 0.4). In contrast the cement mantle thicknesses without a centralizing device varied in the distal region between 3.38 mm and 5.09 mm (p ≤ 0.001) and in the central region between 3.52 mm and 4.19 mm (p ≤ 0.009). CONCLUSIONS A distal centralizer allows a more uniform cement mantle and neutral alignment even with a malinsertion of the femoral stem. This could reduce the failure rate and early loosening in complex THA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of a distal centralizer on the positioning of an anatomical stem.

Femoral stem centralizers were originally designed for double tapered, straight stems. In a slightly modified configuration, the PMMA centralizer is plugged in a hole in the tip of the ABG II femoral prosthesis. The purpose of this study was to determine the effect of the centralizer on the position of the anatomical ABG II stem. Thirty-nine cemented ABG II stems with a centralizer were compare...

متن کامل

No benefit of a proximal stem centralizer in cementing of a femoral prosthesis in human cadavers

BACKGROUND AND PURPOSE A proximal stem centralizer may be beneficial regarding cementing pressures, cement penetration, and stem alignment. We measured these parameters when cementing a mat-surfaced femoral component with and without the use of a proximal stem centralizer. MATERIAL AND METHODS 8 femoral prostheses with proximal centralizers and 8 femoral prostheses without proximal centralize...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Distal stem features improve the torsional resistance of long-stem cemented revision hip stems: an in vitro biomechanical study.

When proximal bone stock is compromised at revision hip arthroplasty, distal fixation is often relied upon for stability of the femoral component. In such circumstances, torsional forces can result in debonding and loosening. This study compared the torsional behaviour of a cemented, polished and featureless (plain) stem with cemented, polished stems featuring fins or flutes. The finned stem co...

متن کامل

CT analysis of defects of the cement mantle and alignment of the stem: in vitro comparison of Charnley-Kerboul femoral hip implants inserted line-to-line and undersized in paired femora.

Using a modern cementing technique, we implanted 22 stereolithographic polymeric replicas of the Charnley-Kerboul stem in 11 pairs of human cadaver femora. On one side, the replicas were cemented line-to-line with the largest broach. On the other, one-size undersized replicas were used (radial difference, 0.89 mm sd 0.13).CT analysis showed that the line-to-line stems without distal centraliser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2015