Temporomandibular Joint Arthroplasty Using Metal-on-Metal and Acrylic-on-Metal Configurations : Wear In Laboratory Tests and In Retrievals.

نویسندگان

  • A L Lippincott III
  • J M Dowling
  • D Phil
  • J B Medley
  • R W Christensen
چکیده

In the long-term performance of the temporomandibular joint (TMJ) implant, wear and durability must be considered. Thus retrieved and laboratory test implants were examined both optically and in a scanning electron microscope (SEM). In laboratory testing, the volumetric wear of metal-on-metal was about an 10x order of magnitude less than that of metal-onacrylic TMJ implants. This metal-on-metal wear was also about 1/60 of that reported in the literature for a laboratory test of (UHMWPE) polyethylene-on-metal TMJ implants. The retrieved TMJ implants showed some abrasive wear occurred during multi-directional articulation with smaller wear zones for the metal-on-metal compared to the metal-on-acrylic configuration. Further efforts to characterize and minimize wear were recommended as prudent in the continuing development of TMJ arthroplasty. In TMJ laboratory wear testing, the protocol for mass loss measurements must be improved to yield realistic and repeatable mass loss values. In laboratory wear testing, multidirectional motion must be imposed in the surface articulations. Further examination of retrieved TMJ implants is required, particularly in-situ for more than 10 years. The retrieval process should include study of tissue samples collected from surrounding tissues so that both the wear particles and the response to wear particles can be studied. New approaches in design and materials should be explored to further reduce wear. INTRODUCTION The metal-on-metal temporomandibular joint (TMJ) implant is not a new concept to the oral and maxillofacial surgeon. In the early 1970’s, Kiehn et al reported on the clinical use of a Christensen Fossa-Eminence component mated with a Cargill-Hahn condyle component. Both of these were made of cast cobalt-chromium-molybdenum (Co-Cr-Mo) metal alloy (Vitallium®). They reported a short-term follow-up of 27 cases, which were rated as successful through reduction of pain and increase in the range of motion and jaw opening. 2 The acrylic-on-metal TMJ implant also has a long history of application in oral and maxillofacial surgery. In addition, acrylic (PMMA or polymethylmethacrylate) was used for the articular surface of a femoral head implant for hip hemiarthroplasty by Judet and Judet in the early 1950’s. Mechanical failure of the Judet hip prosthesis forced discontinuance of the device after a decade of use. For acrylic-on-metal TMJ implants, the relevant issues in long term performance are the wear and tissue response to wear particles. 1 Other polymeric materials have been used for TMJ implants with very poor results. Oral maxillofacial surgeons are familiar with the pain, foreign body reaction, and bone loss caused by particles generated from Proplast-Teflon and Silastic materials that were used in TMJ implants. The purpose of the present study is to examine the wear of both metal-on-metal and acrylic-on-metal Christensen TMJ implants. This study includes the comparison of retrieval implants (up to 11 years) with laboratory wear test implants. The assessment includes the measurement of changes in the macrogeometry with a three dimensional profiling system and the examination of the microgeometry with a SEM. The focus of the present study is to begin to characterize wear behavior of these two implant systems and thus, eventually evaluate the risk of clinical complications associated with wear particle release into surrounding tissues. The aim of the overall development program is to provide a well-engineered TMJ implant system with minimal risk of either short or long-term complications. NOMENCLATURE The average wear of Co-Cr-Mo metal-on-metal TMJ implants in laboratory tests for 2 million cycles was 0.197 mm / million cycles. When compared with wear in laboratory testing of other TMJ implants with different material combinations, the metal-on-metal had the lowest wear. The average wear of acrylic-on-metal TMJ implants in laboratory tests for 2 million cycles in a simulator apparatus was 1.64 mm/million cycles. (Approximately 8 times metal-onmetal) This was almost exclusively on acrylic condylar heads. Examination of the wear tested acrylic and metal components optically and in the SEM showed single wear zones with parallel surface scratches oriented in the uniaxial direction of motion imposed by the wear test apparatus. These scratches seemed deeper and more numerous on the metal-onmetal implant surfaces. In both implant types, the mechanism of wear appeared to be abrasion with additional “third body” abrasion by carbides detached from the metal surfaces. Examination of retrieved metal-on-metal TMJ implants, optically and in the SEM, showed evidence of abrasive wear, in particular “third body” abrasion by detached surface carbides. Two wear zones and random oriented scratches were on each. Upon optical and SEM examination of retrieved acrylicon-metal TMJ implants, there was almost zero wear of the metal fossa component. There was a single large saddle-shaped wear zone on the acrylic condylar head, with randomly oriented scratches. Evidence was found for abrasive wear with additional “third body” abrasion caused by carbides detached 1 Copyright © #### by ASME Copyright © 2005 by ASME from the metal fossa surface. The randomly oriented surface scratches of the retrieved implants indicated that multidirectional motion occurs in the articulation of TMJ implants in vivo. The laboratory wear test apparatus did not represent all of the features of the TMJ implants in vivo with regards to the kinematic detail and contact mechanics, but the results could still provide useful information on TMJ implant performance. For example, the abrasive wear occurring in both material combinations and the amount of wear in the metal-on-metal TMJ implants was comparable to that reported for laboratory testing of metal-on-metal hip implants in the orthopedic literature. Furthermore, the lowest wear in laboratory testing occurred for the metal-on-metal implants, compared with the acrylic-on-metal or polyethylene-on-metal implants. The same ranking of wear performance is expected to occur in vivo. Use of metal-on-metal as an articulating surface for load bearing joints has been criticized in the literature. It was stated that a metal-on-metal combination of materials would produce “galling” and lead to catastrophic failures. While galling may occur in some softer metal materials, such as the stainless steel or titanium alloys, harder cobalt-based alloys are known to be very wear resistant materials in their industrial applications. It is true that the wear test in this study produced a rough, dull surface with parallel scratches over the wear zone due to uniaxial reciprocating motion. However, the surface profile measurements indicated low material loss occurred – leading one to believe that minimal wear debris was produced. The retrieval implants exhibited a “smooth and shiny” wear zone surface to the naked eye, much different in appearance from the laboratory wear test surfaces. The multi-directional motions of the mating Co-Cr-Mo components in vivo, along with an abrasive slurry of small carbides, must be the mechanism to produce these “lapped and highly polished” wear zone surfaces. The wear was not sufficient to suggest any risk of device failures in either the laboratory tested or the retrieved implants. Thus, the statements predicting catastrophic failure of metalon-metal implants, made of Co-Cr-Mo, are not justified. Retrieved and laboratory tested acrylic-on-metal implants have shown higher wear than metal-on-metal implants in both the laboratory wear tests and implant retrievals. Although a correspondingly larger volume of acrylic wear in particulate form is generated in vivo, no report of deleterious foreign body reaction in surrounding tissue has been found in the oral maxillofacial literature. Some long-term retrievals (20 to 40 years) of orthopedic Judet hip implants showed high acrylic wear, yet no significant adverse tissue reaction. Wear particle-induced osteolysis is a new issue that must be considered in the development of implants for load bearing joints. Osteolysis development is dependent upon (1) volume of particles accumulated, (2) particle size and shape, and (3) the threshold levels of particles that surrounding tissues, within an individual patient, can tolerate. The influence of these factors on osteolysis involving cell phagocytosis of particles through the release of tissue destructive biological substances, is the focus of current implant research. New designs are being explored to reduce the volume of particles. This research includes improving the material composition and manufacturing methods of the Co-Cr-Mo alloys to reduce wear. Research centers have looked at various heat treatments, the alloy composition in the generation of microstructure carbides, and the “sliding contact” microstructure deformation processes with twinning and stacking fault energies, as an explanation for the superior wear resistance of Co-Cr-Mo. 2 New methods of decreasing wear, such as coating Co-CrMo with various diamond-like carbon (DLC) coatings, have demonstrated improved wear resistance with effective corrosion resistance and biocompatibility. Adhesion of the coating to the substrate is critical and is in on-going research. Both laboratory testing and retrieval analysis of the metalon-metal Christensen TMJ System show that the use of these implants for combating temporomandibular joint disease is a viable option for the oral and maxillofacial surgeon. ACKNOWLEDGMENTS The author would like to thank Eric J. Northcut, Rose Musculoskeletal Research Laboratory, Denver CO, for his assistance in supplying information and performing the wear testing of the TMJ devices. Appreciation is also expressed to Dr. Maria R. Pintado from the Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, Minneapolis MN, for preparing the surface profile measurements on the wear test implants. I thank Dr. Subrata Saha, Professor, Dept. of Bioengineering, College of Engi-neering and Science, Clemson University, Clemson SC, for hisdetailed testing / study of TMJ implants in contact mechanics. REFERENCES1. Kiehn CL, DesPrez JD, Converse CF. A new procedure fortotal temporomandibular joint replacement. Plastic &Reconstructive Surgery 1974; 53 (2): 221-6.2. Kiehn CL, DesPrez JD, Converse CF. Total prostheticreplacement of the TMJ. Annal Plastic Surg 1979; 2 (1): 5-15.3. Morgan DH. Development of alloplastic materials for tem-poromandibular joint (TMJ) prosthesis: A historical perspectiveand clinical illustrations, J Cranio Prac 1992; 10 (3): 192-204.4. Judet J, Judet R. Use of artificial femoral head for arthroplasty of hip joint. J Bone & Joint Surg 1950; 32B (2): 166-73.5. Scales JT. Biomechanical problems of the original Judetprosthesis. Brit Med J 1954; May: 1007-13.6. Chuong R, Piper MA, Boland TJ. Recurrent giant cellreaction to residual Proplast in the temporomandibular joint.Oral Surg Oral Med Oral Pathol 1993; 76 (1): 16-9.7. Chan FW, Bobyn JD, Medley JB, et al. Wear and lubricationof metal-on-metal hip implants. Clin Orthop 1999: submitted.8. Anspach, Inc. 510k FDA notification Number K954224,subsection entitled “TMJ Wear Test,” Sept 1, 1995.9. Fontenot MG, Kent JN. In vitro wear performance of Pro-plast TMJ disc implants. J Oral Maxillo Surg 1992; 50: 133-9.10. Zamudio L, Gil-Orbezo F, Hernandez-Mercado G. Anacrylic Judet hip prosthesis in a shoulder hemiarthroplasty for 39 years – a case report. SICOT 1997; 21: 91-2.11. Lippincott AL, Chase DC, Christensen RW. Alternativetotal TMJ arthroplasty: Metal-on-metal for longevity in implantsurvivorship. Surg Tech Intl VII 1998: 425-35.12. Willert HG, Bertram H, Buchhorn GH. Osteolysis inalloarthroplasty of the hip. Clin Orthop 1990; 258: 95-107. 13. Clemow AJT, Daniell BL. The influence of microstructureon the adhesive wear resistance of Co-Cr-Mo alloy. Wear1980; 61: 219-31.14. Semlitsch M, Streicher RM, Weber H. Wear behavior: castCoCrMo cups and balls in long-term implanted total hipprostheses. Orthopade 1989; 18: 377-81. 15. Rajan M, Vander Sande JB. Room temperature strengthen-ing mechanisms in a Co-Cr-Mo alloy. J Mater Science 1982;17: 769-78.16. Franks J, Enke K, Richardt A. Diamond-like carbon pro-perties & applications. Metals Materials 1990; Nov: 695-700. 2Copyright © #### by ASMECopyright © 2005 by ASME

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear.

Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clin...

متن کامل

Modern Alternative Bearing Surfaces for Total Joint Arthroplasty

The biologic response to polyethylene particulate debris generated from metalonpolyethylene bearing surfaces is thought to be largely responsible forperiprosthetic osteolysis and aseptic loosening in total joint arthroplasty. As a result, there has been an interest in developing polyethylene with improved wear characteristics, as well as a renewed interest in alternative bearing surfaces for to...

متن کامل

Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing.

Introduction etal-on-metal bearings for hip replacement are gaining popularity as an alternative to the most widely used bearing couple of metal on polyethylene. The recent resurgence of hip resurfacing with the socalled third and fourth generations of hip resurfacing arthroplasty devices has played a substantial role in the wider use of metal-on-metal bearings. Concerns about the wear of polye...

متن کامل

Nanotoxicology of metal wear particles in total joint arthroplasty: a review of current concepts.

Metal-on-metal (M-M) joint replacement has raised concerns about the long-term effects of metal wear debris and corrosion products. This review summarizes the current concepts in biological reactivity to metal wear particles, ions, and corrosion products. Attention is focused on Co-Cr-Mo alloy since it is the most diffused and discussed material in arthroplasty.

متن کامل

A comparison of explanted Articular Surface Replacement and Birmingham Hip Resurfacing components.

The Articular Surface Replacement (ASR) hip resurfacing arthroplasty has a failure rate of 12.0% at five years, compared with 4.3% for the Birmingham Hip Resurfacing (BHR). We analysed 66 ASR and 64 BHR explanted metal-on-metal hip replacements with the aim of understanding their mechanisms of failure. We measured the linear wear rates of the acetabular and femoral components and analysed the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Surgical technology international

دوره 8  شماره 

صفحات  -

تاریخ انتشار 1999