In hematopoietic stem cell transplantation, donor selection is based primarily on matching donor and patient HLA genes. These genes are highly polymorphic and their typing can result in exact allele assignment at each gene (the resolution at which patients and donors are matched), but it can also result in a set of ambiguous assignments, depending on the typing methodology used. To facilitate rapid identification of matched donors, registries employ statistical algorithms to infer HLA alleles from ambiguous genotypes. Linkage disequilibrium information encapsulated in haplotype frequencies is used to facilitate prediction of the most likely haplotype assignment. An HLA typing with less ambiguity produces fewer high-probability haplotypes and a more reliable prediction. We estimated ambiguity for several HLA typing methods across four continental populations using an information theory-based measure, Shannon's entropy. We used allele and haplotype frequencies to calculate entropy for different sets of 1,000 subjects with simulated HLA typing. Using allele frequencies we calculated an average entropy in Caucasians of 1.65 for serology, 1.06 for allele family level, 0.49 for a 2002-era SSO kit, and 0.076 for single-pass SBT. When using haplotype frequencies in entropy calculations, we found average entropies of 0.72 for serology, 0.73 for allele family level, 0.05 for SSO, and 0.002 for single-pass SBT. Application of haplotype frequencies further reduces HLA typing ambiguity. We also estimated expected confirmatory typing mismatch rates for simulated subjects. In a hypothetical registry with all donors typed using the same method, the entropy values based on haplotype frequencies correspond to confirmatory typing mismatch rates of 1.31% for SSO versus only 0.08% for SBT. Intermediate-resolution single-pass SBT contains the least ambiguity of the methods we evaluated and therefore the most certainty in allele prediction. The presented measure objectively evaluates HLA typing methods and can help define acceptable HLA typing for donor recruitment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Charting improvements in US registry HLA typing ambiguity using a typing resolution score.

Unrelated stem cell registries have been collecting HLA typing of volunteer bone marrow donors for over 25years. Donor selection for hematopoietic stem cell transplantation is based primarily on matching the alleles of donors and patients at five polymorphic HLA loci. As HLA typing technologies have continually advanced since the beginnings of stem cell transplantation, registries have accrued ...

متن کامل

Performance of LIFECODES HLA-DQB1 Typing Kit Using Luminex Platform in Koreans

Intermediate-resolution HLA-DQ typing has gained importance in organ transplantation recently. We evaluated the performance of the LIFECODES HLA-DQB1 typing kit (Immucor, USA) using sequence-specific oligonucleotide (SSO) probe and Luminex platform (Luminex Corp., USA) on 100 samples tested by sequence-based typing (SBT) using the AlleleSEQR HLA-DQB1 kit (Abbott Molecular, USA) in Korean indivi...

متن کامل

High-Resolution HLA-A Typing in Normal Iranian Population

Background: Human leukocyte antigen (HLA) gene is a highly polymorphic region. HLA typing is required to match patients and donors for transplantation; therefore, development of HLA registries is necessary for finding HLA match donors. HLA system is highly informative, and numerous studies have been conducted on HLA allele distribution in different populations. Methods: In this study,...

متن کامل

Mesenchymal stem cells as a reference cell for HLA-typing

Introduction: Recognition of human leukocyte antigens (HLA) is of importance for hematopoietic stem cell transplantation. Any HLA-mismatches between the donor and recipient can cause graft rejection or other complications. In HLA-typing experiments, usage of HLA-known reference cells accompany with HLA-unknown samples is obligatory. Some international centers represent these cells with high e...

متن کامل

Typing of HLA Class I by Polymerase Chain Reaction-Sequence Specific Oligonucleotide Primer (PCR-SSOP) Technique in Iranian Cord Blood Donors

Background: HLA compatibility between transplant donor and recipient is one of the major determinants of transplant outcome. Objective: To determine HLA class I by PCR- Sequence-Specific Oligonucleotide Probe (PCR-SSOP) in cord blood donors. Methods: Genomic DNA of 142 cord blood samples registered at the Cord Blood Bank of Iran at Hematology, Oncology, and Bone Marrow Transplantation Researc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012