Interference elimination studies during the determination of trace elements in cow liver using differential pulse polarography
نویسندگان
چکیده
The liver is known to accumulate many trace elements; thus it is very important to determine their level in a sensitive way. The objective of this study was to develop a simple method for the simultaneous determination of trace elements in cow liver in which the elimination of interference can be accomplished. It was observed that Cd, Pb, Zn, and Cu ions could not be determined correctly in the presence of Se(IV), because of interference of Se. It was shown that this interference could be eliminated by using pH 8.5 NaAc electrolyte. In this medium first Cd and Zn were determined; then, after addition of EDTA, Pb and Cu ions were determined by standard addition. Since Ti(IV), Mo(VI), Cr(III), and Fe(III) had no interference with Se(IV) they could be determined at appropriate electrolyte conditions. Selenite, on the other hand, was determined using its hydrogen catalytic peak. The results obtained under 2 conditions, where interference was eliminated and not eliminated, were compared. It was found that the quantities for Cu, Cd, Pb, and Zn were larger in medium where interference does not take place.
منابع مشابه
Selective Determination of Trace-Bismuth by Extraction-Differential Pulse Polarography in Non-Aqueous Media
The voltammetric characteristics of bismuth(III)-oxinate in chloroform at the mercury electrode were investigated and a quasi-reversible behavior for Bi(III) oxinate reduction was confirmed. Preceded by the extraction of Bi(III) oxinate in chloroform, differential pulse polarography was developed in the extracts for determination of the trace-bismuth. The linear range of the calibration gra...
متن کاملDifferential Pulse Polarographic Determination of Trace Antimony in Standard Biological Samples after Preconcentration Using 2-Nitroso-1-naphthol-4-sulfonic Acid
A highly selective, sensitive, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of antimony in various standard alloys and biological samples after adsorption of its 2-nitroso-1-naphthol-4-sulfonic acid - tetradecyldimethylbenzylammonium chloride on microcrystalline naphthalene in the pH range of 7.5-11.0. After filtratio...
متن کاملSimultaneous Determination of Traces of Lead and Cadmium in Various Samples by Differential Pulse Polarography after Adsorbing Their 1-(2-Pyridyazol)-2-Naphthol onto Microcrystalline Naphthalene
A highly selective, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of cadmium and lead present together in various standard alloys and biological samples after adsorption of their 1-(2-pyridylazo)-2-naphthol complexes on microcrystalline naphthalene. Cadmium and lead complexes are equantitatively adsorbed on microcrysta...
متن کاملCOLUMN PRECONCENTRATION OF URANIUM BY 1 -(2-PY RIDYLAZ0)-2-NAPHTHOL SUPPORTED ON NAPHTHALENE USING DIF'FERENTLAL PULSE POLAROGRAPHY
A solid chelating material, 1-(2-pyridy1azo)-2-naphthol (PAN) supported on naphthalene provides a rapid and highly selective means of preconcentration of uranium from aqueous solution. Uranium is quantitatively retained on this adsorbent in the pH range 9.8-10.7 with a flow rate of 1 ml min . The metal complex was desorbed with 10 ml of 2 M hydrochloric acid and uranium is determined by d...
متن کاملA new and simple DP polarographic method for the determination of uric acid in serum after elimination of the interference of ascorbic acid and dopamine
Determination of trace amounts of uric acid (UA) in serum is of great importance since its level in serum may show disorders in purine metabolism. With this method, trace amounts of UA in blood serum can be determined by a fast and simple procedure using differential pulse polarography (DPP). The limit of detection was estimated to be 2 × 10−7 M (S/N = 3), lower than that given in previous stud...
متن کامل