In vivo histological evaluation of non-insulated microneedle radiofrequency applicator with novel fractionated pulse mode.
نویسندگان
چکیده
INTRODUCTION Microneedle radiofrequency is a novel method that allows non-thermal penetration of the epidermis followed by RF coagulation in selected depth of the dermis surrounded by zone of non-coagulative volumetric heating. The first generation of Microneedle RF applicators used insulated needles. These treatments were limited by a few factors, including low volume of dermal heating, lack of effect in the papillary dermis and pinpoint bleeding during the treatment. The system tested in this study (EndyMed PRO, Intensif applicator, EndyMed Medical, Cesarea, Israel) utilizes special extra sharp tapered non-insulated microneedles and a special pulse mode, allowing full coagulation during treatment and higher effective volume of dermal heat. METHODS After Ethics Committee approval, one female pig (Type Large white X Landrace, 34 Kg) was chosen for the study. The animal was anesthetized using Ketamine, Xylazin and Isofluran. The EndyMed PRO, Intensif applicator (was used for treatment with different needle depth penetration (1 mm-3.5 mm) and in multiple energy settings. Six mm punch biopsies were harvested for histological analysis at the following time points: immediately after the treatment, 4 days after the treatment and 14 days after the treatment. H&E and Masson-Trichrome stains were processed. RESULTS Visual inspection of the treated skin, immediately after the treatment, revealed arrays of pinpoint erythematous papules surrounded by undamaged epidermal tissue. Treatment field showed no sign of bleeding. Mild to moderate Erythema and Edema developed a few minutes after the treatment, varying according to the total energy delivered. The histologies taken 4-day after therapy showed in all energy settings, dry micro crusts over the treatment zones, with full healing of epidermis. In the 14-day specimens there was a replacement of the crusts/debris by a normal looking stratum corneum with complete healing of epidermis and dermis. DISCUSSION The current in vivo study confirms that the EndyMed PRO Intensif applicator effective and predictable tool to create cylindrical micro zones of coagulation in the papillary and reticular dermis with minimal damage to the epidermis. The histologies taken 4 days and 14 days after treatment show rapid epidermal renewal with predictable volume of coagulation in dermis related to the length of the needle and the power used. Coagulation of capillaries during treatment allows a dry treatment field. The predictability of the effect and minimal downtime may offer a significant advantage over treatments with ablative fractional lasers of insulated RF microneedles.
منابع مشابه
Lasers in Surgery and Medicine Long-Term Three-Dimensional Volumetric Assessment of Skin Tightening Using a Sharply Tapered Non-Insulated Microneedle Radiofrequency Applicator With Novel Fractionated Pulse Mode in Asians
Background andObjective:Non-insulatedmicroneedle radiofrequency (NIMNRF) is a novel method that allows non-thermal penetration of the epidermis followed by radiofrequency (RF) coagulation at selected depths of the dermis that are surrounded by a zone of non-coagulative volumetric heating. The objective of this study was to investigate subjectively and objectively the efficacy of a single fracti...
متن کاملElectromagnetic Initiation and Propagation of Bipolar Radiofrequency Tissue Reactions via Invasive Non-Insulated Microneedle Electrodes
Radiofrequency (RF) energy can be emitted into the skin, either non- or invasively, via a monopolar mode that utilizes an active electrode and a grounded electrode or via a bipolar mode that employs two active electrodes. In this experimental study of RF tissue reactions, bipolar RF energy was emitted in vivo to micropig skin at varying microneedle penetration depths, signal amplitudes, and con...
متن کاملQuality of life in patients with primary axillary hyperhidrosis before and after treatment with fractionated microneedle radiofrequency
BACKGROUND Primary axillary hyperhidrosis (PAH) is a common condition with a great impact on the patient's quality of life (QOL). It is associated with serious social, emotional, and occupational distress. The aim of this study was to investigate the QOL in patients with PAH before and after treatment with fractionated microneedle radiofrequency (FMR). MATERIALS AND METHODS We evaluated 25 pa...
متن کاملNon-insulated microneedle fractional radiofrequency for the treatment of scars and photoaging.
Editor First described by Manstein and Anderson, fractional techniques have revolutionized the management of numerous dermatological conditions, leading to the development of fractional lasers and fractional radiofrequency devices. A retrospective study was carried out on consecutive patients treated with a non-insulated microneedle fractional radiofrequency (NIMFRF) device: Secret (Ilooda, 2 K...
متن کاملHistometric analysis of skin-radiofrequency interaction using a fractionated microneedle delivery system.
BACKGROUND Fractionated microneedle radiofrequency (RF) devices have been reported to be effective in treatment of various dermatologic disorders. OBJECTIVES To analyze histometric changes in skin-RF interactions using a fractionated microneedle delivery system. MATERIALS AND METHODS RF energies were delivered using a fractionated microneedle device to an in vivo minipig model with penetrat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of drugs in dermatology : JDD
دوره 12 12 شماره
صفحات -
تاریخ انتشار 2013