Pressures in the Plal Arterial Microcirculation of the Cat during Changes in Systemic Arterial Blood Pressure
نویسنده
چکیده
Dynamic arterial blood pressures were recorded by micropuncture of 99 cortical surface arteries and arterioles in cats anesthetized with pentobarbital or chloralose and urediane, using the Wiederhielm servocontrolled micropipette pressure system incorporating pipette tips less than 0.5/A in diameter. During these measurements, systemic blood pressure was varied by supplemental intravenous administration of barbiturate, by intravenous administration of norepinephrine, or by arterial hemorrhage and reinfusion. Pial arterial blood pressure varied systematically with the changes in systemic blood pressure, forming a basis for analysis and synthesis of the results. Measurements in individual vessels indicated that the range of pressures and of pressure responses of the cortical surface vessels was variable with both vessel size and prevailing end-expiratory gas CO2 content. Pooled data indicated that 398 of the loss in pressure head occurred in arteries upstream from the largest (300/x or more in diameter) surface arteries, 21% between these arteries and surface arterioles 50^/. or less in diameter, and 40% downstream from the surface arterioles at a systemic blood pressure of 50 mm Hg. At a systemic blood pressure of 180 mm Hg the upstream loss decreased to 33%, loss across the pial vessels decreased to 15%, and the downstream loss increased to 52%. Thus, the results indicated that the cerebrovascular response to changes in systemic blood pressure occurred predominantly downstream from the surface arterial vasculature.
منابع مشابه
Pressures in the pial arterial microcirculation of the cat during changes in systemic arterial blood pressure.
Dynamic arterial blood pressures were recorded by micropuncture of 99 cortical surface arteries and arterioles in cats anesthetized with pentobarbital or chloralose and urediane, using the Wiederhielm servocontrolled micropipette pressure system incorporating pipette tips less than 0.5/A in diameter. During these measurements, systemic blood pressure was varied by supplemental intravenous admin...
متن کاملثبات همودینامیک با کدام رژیم هوشبری در جراحی پیوند رگهای کرونر قلب بیماران تحت درمان با بتا-بلوکر بیشتراست؟سوفنتانیل سیس - آتراکوریوم یا سوفنتانیل-پانکرونیوم
Background and Aim: Hemodynamic stability during anesthesia and operation is the most important aim of anesthesiologists. Every anesthetic drug has its own hemodynamic effects. The interaction of these drugs with each other and with preoperative drugs of the patients, may cause critical changes in patient's hemodynamic status. For a perfect anesthesia induction, while using high doses of op...
متن کاملTHE EFFECTS OF CAPTOPRIL ON PULMONARY AND SYS TEMIC ARTERIAL PRESSURES IN HIGHALTITUDE PULMONARY HYPERTENSION
The purpose of this investigation was to assess the effect of captopril on both systemic (P.a) and pulmonary arterial pressures (PPA) in patients with high-altitude pulmonary hypertension (HAPH). Seventeen patients (mean age 44±6.8 years) with HAPH and mild to moderate systemic arterial hypertension were included in the study. All patients underwent right heart catheterization with measurem...
متن کاملتأثیر بازآموزی ساکشن لوله داخل تراشه برای پرستاران، بر تغییرات فشارخون بیماران بستری در بخش مراقبت ویژه
Background & Aim: Endotracheal suctioning (ETS) is a common invasive nursing procedure. Hemodynamic parameters changes during and after the procedure. If appropriate strategies do not be applied during the ETS, hemodynamic changes can be significant and life threatening in critically ill patients. The purpose of this study was to assess the effect of education of endotracheal suctioning on pati...
متن کاملCARDIOVASCULAR RESPONSES TO HYPERCAPNIA AND VARYING LEVELS OF ARTERIAL pH IN THE ANESTHETIZED CAT
Effects of acute hypercapnia on the cardiovascular system (CYS) were studied in the anesthetized cat. After surgery the animal was exposed to a gas mixture of 12% CO2 and 25% O2 in nitrogen, and hypercapnia with low levels of arterial pH (pHa) was produced for 20 minutes. In the second run the same level of hypercapnia was induced by ventilating the same cat from the above gas mixture but ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005