Adhesive-based liquid metal radio-frequency microcoil for magnetic resonance relaxometry measurement.

نویسندگان

  • Tian Fook Kong
  • Weng Kung Peng
  • Trung Dung Luong
  • Nam-Trung Nguyen
  • Jongyoon Han
چکیده

This paper reports the fabrication and characterization of an adhesive-based liquid-metal microcoil for magnetic resonance relaxometry (MRR). Conventionally, microcoils are fabricated by various techniques such as electroplating, microcontact printing and focused ion beam milling. These techniques require considerable fabrication efforts and incur high cost. In this paper, we demonstrate a novel technique to fabricate three-dimensional multilayer liquid-metal microcoils together with the microfluidic network by lamination of dry adhesive sheets. One of the unique features of the adhesive-based technique is that the detachable sample chamber can be disposed after each experiment and the microcoil can be reused without cross-contamination multiple times. The integrated microcoil has a low direct-current (DC) resistance of 0.3 Ω and a relatively high inductance of 67.5 nH leading to a high quality factor of approximately 30 at 21.65 MHz. The microcoil was characterized for ∼0.5 T proton MRR measurements. The optimal pulse duration, amplitude, and frequency for the 90° pulse were 131 μs, -30 dB (1.56 W) and 21.6553 MHz, respectively. In addition, we used the liquid-metal microcoil to perform a parametric study on the transverse relaxation rate of human red blood cells at different hematocrit levels. The transverse relaxation rate increases quadratically with the hematocrit level. The results from the liquid-metal microcoil were verified by measurements with a conventional solenoid coil.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Development of miniaturized, portable magnetic resonance relaxometry system for point-of-care medical diagnosis.

A novel, compact-sized (19 cm × 16 cm) and portable (500 g) magnetic resonance relaxometry system is designed and developed. We overcame several key engineering barriers so that magnetic resonance technology can be potentially used for disease diagnosis-monitoring in point-of-care settings, directly on biological cells and tissues. The whole system consists of a coin-sized permanent magnet (0.7...

متن کامل

A Cryo-cooling Microfluidic Channel Device for Magnetic Resonance (mr) Microscopy System

ABSTRACT The development of a cryo-cooling microfluidic device for reducing the resistive noise of a magnetic resonance (MR) microcoil to improve its signal-to-noise ratio (SNR) in MR microscopy applications is presented. The radiofrequency (RF) spiral coil was cryo-cooled to liquid nitrogen temperature (-196oC) by the integrated microfluidic channels carrying liquid nitrogen for decreasing the...

متن کامل

Design and realization of magnetic nanoparticles detector based on the nonlinear magnetization

Magnetic nanoparticles have been widely used in the field of biotechnology and medicine, which has a great importance to precise and quantitative detection. This paper introduces a magnetic nanoparticles detection device of low cost, high sensitivity and real-time. When the diameter of the magnetic nanoparticles is 20nm, the third harmonic intensity of the induced voltage is in the level of mic...

متن کامل

Microcoil high-resolution magic angle spinning NMR spectroscopy.

We report the construction of a dual-channel microcoil nuclear magnetic resonance probehead allowing magic-angle spinning for mass-limited samples. With coils down to 235 mum inner diameter, this allows high-resolution solid-state NMR spectra to be obtained for amounts of materials of a few nanoliters. This is demonstrated by the carbon-13 spectrum of a tripeptide and a single silk rod, prepare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2012