Intensity Video Guided 4D Fusion for Improved Highly Dynamic 3D Reconstruction
نویسندگان
چکیده
The availability of high-speed 3D video sensors has greatly facilitated 3D shape acquisition of dynamic and deformable objects, but high frame rate 3D reconstruction is always degraded by spatial noise and temporal fluctuations. This paper presents a simple yet powerful intensity video guided multiframe 4D fusion pipeline. Temporal tracking of intensity image points (of moving and deforming objects) allows registration of the corresponding 3D data points, whose 3D noise and fluctuations are then reduced by spatio-temporal multi-frame 4D fusion. We conducted simulated noise tests and real experiments on four 3D objects using a 1000 fps 3D video sensor. The results demonstrate that the proposed algorithm is effective at reducing 3D noise and is robust against intensity noise. It outperforms existing algorithms with good scalability on both stationary and dynamic objects.
منابع مشابه
3D and 4D Seismic Data Integration in Static and Dynamic Reservoir Modeling: A Review
Reservoir modeling is the process of generating numerical representations of reservoir conditions and properties on the basis of geological, geophysical, and engineering data measured on the Earth’s surface or in depth at a limited number of borehole locations. Therefore, reservoir modeling requires an incorporation of the data from a variety of sources, along with an integration of knowledge a...
متن کاملHybrid ultrasound/magnetic resonance simultaneous acquisition and image fusion for motion monitoring in the upper abdomen.
OBJECTIVES The combination of ultrasound (US) and magnetic resonance imaging (MRI) may provide a complementary description of the investigated anatomy, together with improved guidance and assessment of image-guided therapies. The aim of the present study was to integrate a clinical setup for simultaneous US and magnetic resonance (MR) acquisition to obtain synchronized monitoring of liver motio...
متن کاملImproving iterative 4D CBCT through the use of motion information
In Image-Guided RadioTherapy (IGRT) of lung tumors, patients undergo a 4D CT, on the basis of which their treatment is planned. It is implicitely assumed that their breathing motion will not change much throughout the treatment, and remain close to what it was during the 4D CT acquisition. During the treatment, several cone beam CT acquisitions are performed, and used to re-position the patient...
متن کاملThe Integration of Automatic Segmentation and Motion Tracking for 4D Reconstruction and Visualization of Musculoskeletal Structures
The 3D reconstruction of high contrast anatomical structures has been widely explored. However, a class of important clinical problems involves the motion of very complex musculoskeletal structures including the joints, hence a 4D reconstruction is desired. Practical difficulties with 4D reconstruction with MRI include the time required for data acquisition, the resolution required for visualiz...
متن کاملAbstractID: 4788 Title: Model-based statistical image reconstruction for 4D PET
ID: 4788 Title: Model-based statistical image reconstruction for 4D PET Purpose: Four-dimensional (4D) PET can be acquired with gated, dynamic or list mode. In reality, a major problem limiting its clinical application is the poor statistics, since the total coincidence counts in conventional 3D PET are divided into several phase bins and each of them is treated as an independent entity in 4D i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1708.01946 شماره
صفحات -
تاریخ انتشار 2017