چکیده

Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety of orthopedic procedures of the femur. Methods. We retrospectively reviewed our experience of using external fixation for femoral reconstruction. Three subgroups were defined based on the primary reconstruction goal lengthening, deformity correction, and repair of nonunion/bone defect. Factors such as leg length discrepancy (LLD), limb alignment, and external fixation time and complications were evaluated for the entire group and the 3 subgroups. Results. There was substantial improvement in the overall LLD, femoral length discrepancy, and limb alignment as measured by mechanical axis deviation (MAD) and lateral distal femoral angle (LDFA) for the entire group as well as the subgroups. Conclusions. The Ilizarov external fixator allows for decreased surgical exposure and preservation of blood supply to bone, avoidance of bone grafting and internal fixation, and simultaneous lengthening and deformity correction, making it a very useful technique for femoral reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valgus osteotomy by external fixation for treatment for developmental coxa vara

Valgus subtrochanteric osteotomy is the standard surgical treatment for coxa vara. Nevertheless, there is no consensus on the method of fixation and osteotomy technique. There are some reports on employing rigid internal fixation methods that preclude the need of postoperative immobilization. This is a technical description of a valgus osteotomy performed using external fixation with preoperati...

متن کامل

Biomechanical analysis of posterior cruciate ligament reconstruction with aperture femoral fixation.

The goal of this study was to determine whether single-tunnel-double-bundle-equivalent posterior cruciate ligament (PCL) reconstruction using an aperture femoral fixation device better replicated normal knee kinematics than single-bundle reconstruction. Eight fresh-frozen human cadaver knees underwent arthroscopically assisted PCL reconstruction and were examined with a robotic testing system t...

متن کامل

Reconstruction plate fixation of subtrochanteric femoral fractures in children.

Pediatric subtrochanteric femoral fractures are rare and have received limited attention in the literature Treatment is controversial. Different treatment options are used: skin traction, 90/90 skeletal traction, spica casting, cast bracing, internal fixation and external fixation. The aim of this study is to present our results with internal fixation of subtrochanteric femoral fractures in chi...

متن کامل

Functional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study

  Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...

متن کامل

Femoral locking plate failure salvaged with hexapod circular external fixation: a report of two cases

Femoral non-unions are difficult to treat even for the experienced orthopaedic trauma surgeon. If the non-union follows failure of modern stable internal fixation, the complexity of the management is further increased. We report two cases of stiff hypertrophic femoral non-unions after failed locking plate fixation that were successfully treated with a new hexapod circular external fixator. In a...

متن کامل