Phakic intraocular lens implantation for treatment of anisometropia and amblyopia in children: 5-year follow-up.
نویسندگان
چکیده
PURPOSE To evaluate the safety and efficacy during 5-year follow-up of phakic intraocular lens (PIOL) implantation to correct high anisometropia in amblyopic children who were non-compliant with traditional medical treatment including spectacles or contact lenses. METHODS Retrospective study of 10 eyes of 10 children with high anisometropia who underwent PIOL implantation (9 with an iris-supported IOL and 1 with a posterior chamber IOL). Patient age at the time of implantation ranged from 2 to 15 years. Mean preoperative spherical equivalent refraction was -10.14 ± 6.96 diopters (D) (range: +8.00 to -18.00 D). Mean logMAR corrected distance visual acuity (CDVA) was 0.84 ± 0.52. Postoperative data at 6, 24, and 60 months were evaluated. RESULTS Corrected distance visual acuity improved in all children. At 24 months, logMAR CDVA was 0.39 ± 0.35 and at 5 years was 0.36 ± 0.38 (range for both: 0.1 to 1.0) (P=.01). Improvement of more than three logMAR lines of CDVA was achieved in all children except for one (one line improvement) who was implanted with a posterior chamber PIOL. No loss of CDVA was detected in any patient. Five years after surgery, endothelial cell count was >2000 cells/mm(2) in eight (80%) patients; for the remaining two patients, one reported frequent eye rubbing and the other suffered ocular trauma. CONCLUSIONS Phakic IOL implantation in children with anisometropic amblyopia showed a positive long-term impact on visual acuity.
منابع مشابه
Phakic anterior chamber intraocular lens (Verisyse™) implantation in children for treatment of severe ansiometropia myopia and amblyopia: Six-month pilot clincial trial and review of literature
PURPOSE The current study aims to evaluate both safety and efficacy of Verisyse() (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (>-8 D) myopic anisometropia in children who are noncompliant to traditional medical treatment including spectacle correction or contact lenses. DESIGN Retrospective interventional case series. METHODS S...
متن کاملOPTH-5710-Phakic anterior chamber intraocular lens - Verisyse
Correspondence: Amir Pirouzian 710 Lawerence Expressway, Dept 490, Santa Clara, CA 95051, USA Tel +1 408 851 4100 Email [email protected] Purpose: The current study aims to evaluate both safety and efficacy of VerisyseTM (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (-8 D) myopic anisometropia in children who are noncompliant to...
متن کاملThe Role of Phakic Intraocular Lens Implants in Treatment of High-Refractive Errors and Amblyopia in Children
INTRODUCTION This article aims to evaluate the role of phakic intraocular lens (pIOL) implants in the treatment of high-refractive errors and amblyopia in the pediatric setting. METHODS A literature search of the PubMed database was conducted in December 2012 using the keywords: pIOL implants, amblyopia, pediatric refractive surgery and ametropia, and articles of high or medium clinical relev...
متن کاملAnterior chamber iris-fixated phakic intraocular lens for anisometropic amblyopia.
We report a child who had implantation of an iris-fixated Artisan phakic intraocular lens (IOL) to correct high unilateral myopia to support the therapy of anisometropic amblyopia. After IOL implantation, the patient continued occlusion therapy to further treat the amblyopic eye. One year postoperatively, the best corrected visual acuity in the amblyopic eye was 1.00 and binocular stereovision ...
متن کاملReversal of myopic anisometropic amblyopia with phakic intraocular lens implantation.
PURPOSE To report a case of reversal of myopic anisometropic amblyopia with phakic intraocular lens implantation. METHODS A 6-year-old boy with anisometropic amblyopia with spherical equivalent refraction of right eye: -14.00 -3.00 x 100 degrees, left eye: -0.50 -3.25 x 90 degrees, was treated for 2 years with occlusion to the left eye, with poor results. Refractive surgery was planned becaus...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 27 7 شماره
صفحات -
تاریخ انتشار 2011