Power M-Mode Doppler and single-gate spectral analysis using a 2-MHz pulsed-wave Doppler transducer to directly detect cervical internal carotid artery stenosis: use of the continuity principle: report of a novel technique.

نویسندگان

  • Vasile N Popa
  • Merrill P Spencer
  • Charlene L Lion
  • Robert A Felberg
چکیده

BACKGROUND AND PURPOSE We hypothesized that direct cervical investigation with Power M-Mode Doppler (PMD) combined with single-gate Doppler spectral analysis (SGDSA) using a 2-MHz pulsed-wave Doppler transducer would show reasonable accuracy parameters when compared with standard color-coded carotid duplex ultrasound (CDU). METHODS We prospectively screened for cervical internal carotid artery (ICA) stenosis by direct observation using a 2 MHz PMD/SGDSA device. PMD identified the artery (location, depth, flow direction) and SGDSA assessed waveform; peak systolic, end diastolic, and mean flow velocities (MFV) of the common carotid artery; cervical ICA proximally and distally; and external carotid artery. Diagnostic accuracy was compared with concurrent carotid duplex ultrasound. The continuity principle was applied using the proximal/distal cervical ICA MFV ratio. RESULTS We examined 456 vessels (228 patients). Using ICA proximally/ICA distally MFV ratio of 1.5 or greater or absence of ICA signature, for 40% to 59% or greater stenosis (including occlusions), sensitivity was 75.4%, specificity 99.8%, positive predictive value 97.7%, negative predictive value 96.6%, and accuracy 96.7%. For MFV ratio 1.6 or greater or absence of ICA signature and 60% to 79% or greater stenosis (including occlusions), sensitivity was 92.3%, specificity 98.1%, positive predictive value 81.8%, negative predictive value 99.3%, and accuracy 97.6%. CONCLUSIONS Use of combined PMD and SGDSA to directly observe the extracranial ICA is reasonably accurate compared with carotid duplex ultrasound. Using the MFV ratio of proximal/distal extracranial ICA improves accuracy parameters and provides a quick and effective bedside screen for ICA stenosis. This novel technique should be considered part of the standard PMD/transcranial Doppler examination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

بررسی دقت و همبستگی سونوگرافی داپلر رنگی با آنژیوگرافی در تعیین شدت تنگی عروق کاروتید گردنی در بیماران ایسکمی مغزی

This is retrospective double-blind research, which was carried out in Imam Khomeini hospital in order to study the accuracy of color Doppler ultrasonography for detecting the site and grade of stenosis in cervical carotid artery. 40 patients with mean age of 62 years studied with color Doppler before DSA angiography. The most common sites of stenosis were left internal carotid (39.5%) and right...

متن کامل

Transcranial Doppler in cerebrovascular disease.

Thomas JH: Incidence of recurrent stenosis after carotid endarter-ectomy determined by digital subtraction angiography. Digital transvenous angiography in follow-up examinations after carotid reconstruction. SUMMARY Doppler analysis of flow in intracranlal arteries is now possible using a 2 MHz probe allowing sufficient penetration of bone to obtain signals noninvasivety. Thirty-two normal subj...

متن کامل

Pulse Doppler Analysis in External Ophthalmic and the Long Ciliary Ophthalmic Arteries in the Cat

Objective- Analysis of the PSV (peak systolic velocity), EDV (end diastolic velocity) and RI (Resistant Index) in external ophthalmic and the long ciliary ophthalmic arteries in the cat by pulse Doppler. Design- Descriptive study Animals- 12 short haired “Tomcats” weighted about 3.9± 0.9 Kg no e general and optic disease in clinical, paraclinical and ophthalmoscopic examinations. Pr...

متن کامل

Ultrasonic duplex scanning for disease of the carotid artery.

The duplex ultrasonic scanner combines real-time B-mode imaging with a single-gate, variable-range pulsed Doppler. The detection and categorization of the severity of carotid artery atherosclerosis is achieved by performing spectral analysis of the pulsed Doppler velocity signal obtained from vessels of interest. Using this technique, 750 patients with suspected extracranial carotid artery dise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 2007