Comparing the accuracy and precision of SMART1Map, SASHA and MOLLI

نویسندگان

  • Jeff A Stainsby
  • Glenn S Slavin
چکیده

Background Currently, MOLLI [1] is the most common method for measuring myocardial T1. Because MOLLI uses an SSFP-based Look-Locker approach, only the apparent T1 (T1*) can be measured, and there are concerns about the accuracy of the T1* values due to the dependence on imaging parameters. Alternatives to LookLocker imaging are single-point methods such as SASHA[2] and SMART1Map[3]. Although single-point methods are historically well-established and measure true T1, there remain differences between SASHA and SMART1Map that may affect their performance. Although both use single-point saturation recovery to acquire data at multiple saturation delay times (TS), the distribution of delay times is very different (Figure 1). The purpose of this work was to examine the accuracy and precision of MOLLI, SASHA, and SMART1Map in a phantom study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

True T1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac T1 mapping): a comparison with MOLLI

Background SMART1Map is a new single-point technique for cardiac T1 mapping [1]. Unlike Look-Locker approaches, such as MOLLI, which yield an “apparent” T1 (T1*), SMART1Map directly measures true T1. Because T1* is a function of imaging parameters, it is always shorter than T1, and correction methods are required to obtain the true T1. This work compared the accuracy of SMART1Map with MOLLI in ...

متن کامل

Improved precision in SASHA T1 mapping with a variable flip angle readout

Background The SAturation-recovery single-SHot Acquisition (SASHA) T1 mapping sequence has excellent accuracy independent of T1, T2, heart rate, and flip angle [1], which are known dependencies of the more commonly used MOdified Look-Locker Inversion-recovery (MOLLI) sequence. However, SASHA has a greater T1 variability (poorer precision) compared to MOLLI. A two-parameter fit, with assumed ide...

متن کامل

Myocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI

BACKGROUND Myocardial T1-mapping recently emerged as a promising quantitative method for non-invasive tissue characterization in numerous cardiomyopathies. Commonly performed with an inversion-recovery (IR) magnetization preparation at 1.5T, the application at 3T has gained due to increased quantification precision. Alternatively, saturation-recovery (SR) T1-mapping has recently been introduced...

متن کامل

Robust free-breathing SASHA T1 mapping with high-contrast image registration

BACKGROUND Many widely used myocardial T1 mapping sequences use breath-hold acquisitions that limit the precision of calculated T1 maps. The SAturation-recovery single-SHot Acquisition (SASHA) sequence has high accuracy with robustness against systematic confounders, but has poorer precision compared to the commonly used MOdified Look-Locker Inversion recovery (MOLLI) sequence. We propose a nov...

متن کامل

Myocardial T1 mapping using SMART1Map: initial in vivo experience

Background Recently a single-point, saturation-recovery myocardial T1 mapping sequence (SMART1Map = Saturation Method using Adaptive Recovery Times for cardiac T1 Mapping) was presented [1]. Compared to common methods like MOLLI, SMART1Map measures true T1 instead of apparent T1 relaxation, is more time efficient and can track exact TI times instead of estimated ones based on the heart rate dur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014