Hot-Pack and 1-MHz Ultrasound Treatments Have an Additive Effect on Muscle Temperature Increase.
نویسندگان
چکیده
OBJECTIVE Therapeutic ultrasound is an effective deep heating modality commonly applied alone or after cooling or heating of the treatment area. The purpose of this study was to examine the tissue temperature rise in the human triceps surae muscle group after ultrasound with prior heating via a silicate gel hot pack. DESIGN AND SETTING This study was designed as a 2 x 2 x 3 factorial with repeated measures on two factors (depth and time). Independent variables were temperature of pack (hot and room temperature), depth of measurement (1 cm and 3 cm), and time (beginning, after pack application, and after ultrasound). The dependent variable was tissue temperature. Subjects were assigned to one of two treatment groups: ultrasound preceded by a 15-minute hot pack treatment or ultrasound preceded by a 15-minute application with a silicate gel pack at room temperature. Measurements were taken while subjects were treated in a university training room. SUBJECTS Twenty-one uninjured male and female college student volunteers were randomly assigned to one of the two pack groups. MEASUREMENTS The hot packs were stored in 75 degrees C water. A 1-MHz ultrasound treatment was administered for 10 minutes at an intensity of 1.5 W/cm(2). Tissue temperature was measured every 30 seconds using 23-gauge hypodermic microprobes interfaced with a telethermometer and inserted 1 and 3 cm below the surface of anesthetized triceps surae muscle. RESULTS At both tissue depths, there was a 0.8 degrees C greater increase in tissue temperature with hot packs and ultrasound. At 1 cm, ultrasound increased temperature 3.5 degrees C after a 0.5 degrees C rise during the room temperature-pack application, but only 0.6 degrees C after a 3.8 degrees C increase during hot-pack application. At 3 cm, ultrasound increased temperature 3.85 degrees C following a slight (-0.26 degrees C) decrease during the room temperature-pack application and 3.68 degrees C after a 0.74 degrees C increase during hot-pack application. CONCLUSIONS Vigorous increases in deep muscle temperature (>/=4 degrees C) can be reached with 2 to 3 minutes less total sonation time when preheated with a hot pack. Thus, ultrasound and hot packs have an additive effect on intramuscular temperature, but the characteristics of the additive effect are different, primarily because there appears to be a tissue temperature plateau.
منابع مشابه
A Comparison of Six Ultrasound Stimulation Types on Pseudomonas Aeruginosa Growth in Vitro
Background: This work evaluated the efficiency of common ultrasound stimulation (U.S.S) types on bacterial growth in vitro using clinically relevant conditions.Objective: To estimate different frequencies ultrasound bactericidal ability on bacteria in bacteria of Pseudomonas Aeruginosa. Methods: Six types of U.S.S (continuous wave, 7w/cm2, 20 KHz; continuous wave, 35w/0.8L, 40 KHz; continuous ...
متن کاملThe Effects of Local Heating and Cooling of Arm on Maximal Isometric Force Generated by the Elbow Flexor Musculature in Male Subjects
Objectives: It is well known that neuromuscular function is temperature sensitive. Changing of muscle temperature can effect voluntary muscle contraction. The aim of this study was to investigate the effects of cooling and heating on maximal isometric force generated by the elbow flexor musculature in male subjects. Methods: Forty five healthy males encompassing 3 groups participated in the ...
متن کاملEffect of Therapeutic Sequence of Hot Pack and Ultrasound on Physiological Response Over Trigger Point of Upper Trapezius
BACKGROUND Musculoskeletal pain is a common problem among athletes. Apart from sport injuries, the myofascial pain syndrome is another important problem that affects performance of the athlete. OBJECTIVES The aim of this study was to evaluate the effects of therapeutic sequences of the hot pack in combination with ultrasound on the physiological responses over the latent myofascial trigger po...
متن کاملThree-MHz Ultrasound Heats Deeper Into the Tissues Than Originally Theorized.
OBJECTIVE: To measure muscle temperature of ultrasound at 1-MHz and 3-MHz frequencies at a depth of 2.5 cm and to compare treatment durations for vigorous heating (increase of 4 degrees C) and for heating to 40 degrees C. DESIGN AND SETTING: A counterbalanced, repeated-measures design with 1 fixed, independent variable, 1.5-W/cm(2) ultrasound treatment (1 MHz, 3 MHz, or control [sham]) using a ...
متن کاملIntramuscular temperature differences between the mid-point and peripheral effective radiating area with ultrasound.
The purpose of the study was to determine whether uniform intramuscular heating is achieved throughout a treatment area 2 times the transducer head at both 1 and 3 MHz. Seven male and three female subjects (Age: 23.6 ± 1.0 yrs, Weight: 83.8 ± 23.2 kg, Site Skinfold: 13.9 ± 7.3 mm) underwent two ultrasound treatments (1 and 3 MHz) in the triceps surae muscle group. Thermocouples were inserted at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of athletic training
دوره 33 1 شماره
صفحات -
تاریخ انتشار 1998