Indoor Air Quality in U.k. School Classrooms Ventilated by Natural Ventilation Windcatchers

نویسندگان

  • Benjamin M. Jones
  • Ray Kirby
چکیده

The provision of good IAQ in schools is important both for the health of students and in maximising educational achievement. It is, however, common for school classrooms to be significantly under-ventilated and this can lead to high levels of CO 2 and other pollutants. Natural ventilation offers the potential to improve IAQ within schools whilst at the same time reducing running and maintenance costs. Accordingly, this article examines a natural ventilation strategy based on the use of a roof mounted split-duct Windcatcher ventilator. Here, 16 U.K. classrooms are studied and CO 2 , temperature, relative humidity and ventilation rates are measured for the summer and winter seasons. Results show that during the summer months the ventilator is capable of significantly improving ventilation rates as well as reducing CO 2 levels, especially when used in combination with open windows; however, in the winter months, the ventilator is seen not to open for a sufficient length of time and so CO 2 levels rise above those required in the standards. Thus, the ventilator is shown to have the potential to improve IAQ within school classrooms, but the operation of the ventilator should be carefully controlled in order to realise these benefits. It is common for ventilation rates in school classrooms to fall below the levels required by relevant standards. The data presented here demonstrates that by using a top-down natural ventilation Windcatcher as part of a well designed natural ventilation strategy, ventilation rates in school classrooms can be significantly improved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the Use of Windcatchers in Schools: Climate Change, Occupancy Patterns, and Adaptation Strategies

Advanced naturally ventilated systems based on integration of basic natural ventilation strategies such as cross-ventilation and stack effect have been considered to be a key element of sustainable design. In this respect, there is a pressing need to explore the potential of such systems to achieve the recommended occupant comfort targets throughout their lifetime without relying on mechanical ...

متن کامل

An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls' High Schools in Arak, Iran)

As s‌tudents spend one-third of their time at school, their health, comfort, and productivity are mos‌tly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and s‌tudents aren't allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comf...

متن کامل

Energy-efficient air quality control in school classrooms

The aim of the present work is to maximize indoor environmental quality (IEQ), in particular air quality, and energy performance in schools, when having different ventilation alternatives combined with carbon dioxide feedback. In this effort, trial measurements and energy simulations were conducted to predict and compare the indoor environmental and energy performance in an otherwise similar sc...

متن کامل

Indoor air quality in Michigan schools.

UNLABELLED Indoor air quality (IAQ) parameters in 64 elementary and middle school classrooms in Michigan were examined for the purposes of assessing ventilation rates, levels of volatile organic compounds (VOCs) and bioaerosols, air quality differences within and between schools, and emission sources. In each classroom, bioaerosols, VOCs, CO(2), relative humidity, and temperature were monitored...

متن کامل

Indoor Air Quality in Naturally Ventilated Italian Classrooms

Characterization of indoor air quality in school classrooms is crucial to children’s health and performance. The present study was undertaken to characterize the indoor air quality in six naturally ventilated classrooms of three schools in Cassino (Italy). Indoor particle number, mass, black carbon, CO2 and radon concentrations, as well as outdoor particle number were measured within school hou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012