Laboratory evaluation of a low prime closed-circuit cardiopulmonary bypass system.
نویسندگان
چکیده
We have explored the potential advantages of a low prime closed-circuit cardiopulmonary bypass (CPB) system using a non-human primate model. Although manufacturers have reduced priming volumes in individual CPB components, the standard circuit volume remains high because of the tubing diameter and length necessary for gravity drainage. By replacing gravity drainage with the negative pressure generated by a centrifugal pump, we can realize significant tubing volume reduction. Closed-circuit bypass was conducted on 13 baboons ranging from 5-15 kg. The circuit consisted of a centrifugal pump, a hollow fiber oxygenator, and 1/4" arterial and venous tubing. The design of the circuit included the capacity to remove a limited amount of venous air. Circulatory arrest during deep hypothermia with volume displacement into a reservoir was also accomplished with this circuit. The potential benefits of this low prime closed-circuit bypass system include blood conservation and reduction in blood surface area contact. The future safe clinical use of this type of closed-circuit bypass for routine open heart surgery will depend upon the incorporation of a device in the venous line to remove air. This is the greatest threat to patient safety in a closed circuit system and its use for open chest surgery must wait until an efficient venous air elimination device is available.
منابع مشابه
Hematological effects of a low-prime neonatal cardiopulmonary bypass circuit utilizing vacuum-assisted venous return in the porcine model.
Limiting hemodilution in neonates is difficult when extracorporeal circuits require priming volumes that are 2 to 3 times the blood volume of the newborn patient. This extreme hemodilution contributes to the development of significant postbypass coagulation disturbances. The purpose of this project was to design a low-prime neonatal bypass circuit and evaluate the coagulation status after reduc...
متن کاملThe efficacy of low prime volume completely closed cardiopulmonary bypass in coronary artery revascularization.
PURPOSE This study was conducted to evaluate and demonstrate the efficacy of low prime volume completely closed cardiopulmonary bypass (LPVP) in arrested coronary artery bypass grafting (CABG). We improved the percutaneous cardiopulmonary support (PCPS) circuit to reduce the deleterious effects of cardiopulmonary bypass (CPB). METHODS Between April 1999 and May 2003, among 228 isolated CABG p...
متن کاملPediatric orthotopic heart transplant requiring perioperative exchange transfusion: a case report.
An 11-month-old patient with idiopathic cardiomyopathy was scheduled for orthotopic heart transplantation. A perioperative exchange transfusion was performed because of elevated panel reactive antibody levels. This process was accomplished in the operating room prior to instituting cardiopulmonary bypass using a modified cardiopulmonary bypass circuit. In preparation for the procedure, the card...
متن کاملThe Effect of ringer Lactate as the Priming Solution of the Cardiopulmonary by Pass Circuit on Plasma Potassium Levels after Open Heart Surgery in Children
Background: Conduct of cardiopulmonary bypass (CPB) due to the higher volume of priming solution in comparison to the total blood volume in children requires careful consideration. Recently attention has been focused on the potential risk of hyperkalemia in these patients. Given its significant effects on cardiac rhythm, hyperkalemia is considered a medical emergency. In this cross-sectional st...
متن کاملChalk in the prime.
After observations of cloudiness in the perfusion circuit at open intracardiac operations, laboratory experiments showed a precipitate in a Hartmann's solution (compound sodium lactate solution, Ringer-lactate) and sodium bicarbonate based priming fluid used for cardiopulmonary bypass. The precipitate was found to consist of calcium carbonate crystals. The crystals were not dissolved by adding ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 24 4 شماره
صفحات -
تاریخ انتشار 1993