Correlation between MRI results and intraoperative findings in patients with silicone breast implants

نویسندگان

  • Nicole Lindenblatt
  • Karem El-Rabadi
  • Thomas H Helbich
  • Heinrich Czembirek
  • Maria Deutinger
  • Heike Benditte-Klepetko
چکیده

BACKGROUND Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. METHODS Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21-72) years, with a mean duration of implantation of 3.8 (range 1-28) years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. RESULTS Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%). In seven of 17 removed implants (41%), the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. CONCLUSION Our results show that rupture of only the inner layers of the implant shell with integrity of the outer shell leads to a misdiagnosis on MRI. Correlation with clinical symptoms and the specific wishes of the patient should guide the indication for implant removal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Breast Ultrasound Elastography to Differentiate Intracapsular Collection from Silicone-Induced Granuloma of Breast Implant Capsule Complementarily to Contrast-Enhanced Breast Magnetic Resonance Imaging

Background To determine whether there is correlation between magnetic resonance imaging (MRI) findings and breast elastography to differentiate seroma/hematoma from silicone-induced granuloma of breast implant capsule (SIGBIC). Methods Prospective study of 99 patients with breast implants submitted to breast MRI during the period from February 1 to May 1, 2017. Patients who present MRI findin...

متن کامل

Silicone breast implants: correlation between implant ruptures, magnetic resonance spectroscopically estimated silicone presence in the liver, antibody status and clinical symptoms.

OBJECTIVE To determine the impact of implant integrity on clinical symptoms and antibody status in women with silicone breast implants (SBIs). METHODS Ninety consecutive women were examined by means of magnetic resonance imaging (MRI) to assess the integrity of their silicone breast implants. The presence of silicone in the liver was estimated by (1)H localized stimulated echo acquisition mod...

متن کامل

Dual-Energy CT for Evaluation of Intra- and Extracapsular Silicone Implant Rupture

Silicone implants are commonly used for both breast augmentation and breast reconstruction. With aging of the implant, the silicone envelope may become weak or may rupture. The technique of choice for evaluation of implant integrity is breast MRI; however this may be contraindicated in some patients or the cost may be prohibitive. Dual-energy CT allows determination of density and atomic number...

متن کامل

Subacute Arterial Bleeding After Simultaneous Mastopexy and Breast Augmentation with Implants

Breast augmentation with implants is one of the most commonly performed plastic surgery procedures. The goal of the operation is to increase the size, shape or fullness of the breast. It is accomplished by placing silicone, saline or alternative composite breast implants under the chest muscles, fascia or the mammary gland. This type of operation is no exception concerning the occurrence of com...

متن کامل

PIP breast implants: rupture rate and correlation with breast cancer.

AIM To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. PATIENTS AND METHODS 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-...

متن کامل