QRS axis based classification of electrode interchange in wearable ECG devices
نویسندگان
چکیده
Wearable ECG monitoring is becoming a convenient way for patients as well as doctors, in tracking and diagnosing heart diseases among large population in rural areas. Wearable ECG devices along with the smartphones are used to capture and transmit ECG data to hospitals where medical practitioners diagnose and make suitable interventions. ECG electrode cable misplacement poses significant challenge when untrained population is the end-user. We present a real-time lead misplacement detection system for MasonLikar lead configuration to provide immediate feedback to patients. It reduces chances of pseudo-disease diagnosis as well as the need for technicians to confirm the validity and quality of captured ECG data. The field test results show that six different Mason-Likar electrode misplacement can be detected and differentiated from a normal one with a confidence value p=0.05.
منابع مشابه
Clockwise rotation III 2 I 2 II AVL AVF
Incorrect electrode cable connections during electrocardiographic (ECG) recording can simulate rhythm or conduction disturbance, myocardial ischaemia and infarction, as well as other clinically important abnormalities. When only precordial or only limb cables, excluding the neutral cable, have been interchanged the waveforms in the different leads are re-arranged, inverted, or unchanged, wherea...
متن کاملA QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices
In the new-generation wearable Electrocardiogram (ECG) system, signal processing with low power consumption is required to transmit data when detecting dangerous rhythms and to record signals when detecting abnormal rhythms. The QRS complex is a combination of three of the graphic deflection seen on a typical ECG. This study proposes a real-time QRS detection and R point recognition method with...
متن کاملDesign and Realization of Signal Processing Platform of Multi-Parameter Wearable Medical Devices
This paper presents a design of new type of multi-parameter wearable medical devices signal processing platform. The signal processing algorithm has a QRS-wave detection algorithm based on LADT, wavelet transformation and threshold detection with TMS320VC5509 DSP system. The DSP can greatly increase the speed of QRS-wave detection, and the results can be practical used for multi-parameter weara...
متن کاملساخت حسگر پارچهای سیگنال قلب توسط چاپ و لایه نشانی فلز مس روی پارچه پلیاستر
In the last decade, a significant progress has been made in the wearable medical devices. Scientists are extensively involved in the design of the flexible instruments equipped with garments to fulfill the daily needs and requirements. The fulfillment of this demand particularly needs a conductive fabric substrate with a high level of homogeneity, and the lowest barrier against electrical curre...
متن کاملImplementation of Fuzzy-rule based Activity Classification and Optimized Adaptive Filter-set for Wearable ECG Recording
An enhanced and optimized adaptive filter with optimal filter coefficients selection is proposed and implemented to resolve motion artifact issue in wearable ECG Recording. A two-electrode small size chest belt ECG system mounted with 3-axis accelerometer is implemented for ECG and activity ubiquitous recording in daily life. In ubiquitous ECG recording, ECG signal is often distorted due to dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- EAI Endorsed Trans. Future Intellig. Educat. Env.
دوره 2 شماره
صفحات -
تاریخ انتشار 2016