Cryptand derived fluorescence signaling systems for sensing Hg(II) ion: A comparative study.

نویسندگان

  • Kalyan K Sadhu
  • Susan Sen
  • Parimal K Bharadwaj
چکیده

Two laterally non-symmetric aza-oxa cryptands have been derivatized with the electron-withdrawing fluorophore, 7-nitrobenz-2-oxa-1,3-diazole to obtain the corresponding mono-, bis- and tris-products. In each case, no appreciable emission is observed when the fluorophore is excited due to an efficient photoinduced intramolecular electron transfer (PET) from the lone pair on nitrogen present in the bridges. In the presence of a number of transition and heavy metal ions, their emission characteristics change. The electron-withdrawing ability of the fluorophore drastically alters the binding ability of the cryptand such that Hg(ii) affords largest enhancement of fluorescence. In contrast, mono-, bis- and tris-anthryl (electron-donating) derivatives of these cryptands do not exhibit any selectivity towards Hg(ii) and affords low fluorescence enhancement. Also, the difference in cavity dimension of the o-cryptand and m-cryptand plays a crucial role in terms of selectivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescence signaling systems for sensing Hg(II) ion derived from A2B-corroles.

Selective detection of Hg(II) ions in solution by a series of novel free base bis-(nitrophenyl) corroles (1-4) with general formula A(2)B (where A = nitrophenyl, and B = N,N-dimethylaminophenyl, thienyl, naphthyl and tridecyloxyphenyl group) is described. Among the free base corroles, 4, with a tridecyloxy long chain moiety, has been found to exhibit the highest Hg(II) sensing ability. The dete...

متن کامل

Role of spacer in single- or two-step FRET: studies in the presence of two connected cryptands with properly chosen fluorophores.

Two cryptand molecules are connected via p-xyloyl, benzene-1,4-dicarbolyol and 9,10-dimethylene anthracene. Each cryptand is further derivatized with fluorophores such that electronic absorption of one fluorophore overlaps emission of the other. This way, three different systems L(1), L(2) and L(3) have been synthesized to get a better view of the effect on the distance in single- and two-step ...

متن کامل

A cryptand based chemodosimetric probe for naked-eye detection of mercury(II) ion in aqueous medium and its application in live cell imaging.

A cryptand-rhodamine conjugated chemodosimeter can detect Hg(II) ion in aqueous medium selectively at ppb level in the presence of other biologically relevant metal ions and also shows a good viability to the HEK 293 cell line.

متن کامل

Rhodamine-based probes for metal ion-induced chromo-/fluorogenic dual signaling and their selectivity towards Hg(II) ion.

The new signaling probes 2-6, rhodamine-B derivatives of various receptors which contain different donor atoms for effective metal ion coordination, were synthesized and their absorption as well as fluorescence spectral responses were evaluated in the presence of various metal ions. All these probes along with the reference probe 1 have exhibited optimal metal ion-induced absorption and fluores...

متن کامل

Cryptand cage: perfect skeleton for transition metal induced two-step fluorescence resonance energy transfer.

Attachment of three different fluorophores to an aza-oxa cryptand (L) gives a transition-metal ion induced two-step fluorescence resonance energy transfer system.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dalton transactions

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2011