Differential expression of allergens on the internal and external surfaces of latex surgical gloves.

نویسندگان

  • C Peixinho
  • P Tavares
  • M R Tomáz
  • L Taborda-Barata
  • C Tomáz
چکیده

BACKGROUND Differences in latex allergen sensitization profiles have been described between children undergoing repeated surgical interventions and health care workers. The purpose of this study was to determine whether such sensitization profiles are associated with differences in the expression of latex allergen between the internal and external surfaces of surgical gloves. METHODS Extracts were obtained from whole surgical gloves as well as from their external and internal surfaces. The extracts were centrifuged, filtered, concentrated, dialyzed and lyophilized. The protein profile of the extracts was analyzed using hydrophobic interaction chromatography (HIC) and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Immunoblotting was performed using sera from two patients with confirmed latex allergy. Latex recombinant allergen-specific IgE in these two patients was determined using a fluorescence enzyme immunoassay (FEIA) method. Latex allergen quantification was determined on both glove surfaces using an ELISA method. RESULTS HIC and SDS-PAGE showed qualitative and quantitative differences in proteins between the internal and external glove surfaces, with the former being much richer in proteins. Immunoblotting of glove extracts using sera from two latex-allergic health workers showed differences between glove surface extracts. ELISA quantification of latex allergens demonstrated that the internal glove surface had high amounts of Hev b 5 and Hev b 6.02 whereas the external surface showed Hev b 1, Hev b 3, and Hev b 6.02. CONCLUSIONS Our results reveal substantial differences in the composition of latex allergen profiles between the internal and external surfaces of surgical latex gloves, which may suggest a relationship between latex allergen localization and sensitization routes in different risk groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different in vivo reactivity profile in health care workers and patients with spina bifida to internal and external latex glove surface-derived allergen extracts.

BACKGROUND Allergy to natural rubber latex is a well-recognized health problem, especially among health care workers and patients with spina bifida. Despite latex sensitization being acquired in health institutions in both health care workers and patients with spina bifida, differences in allergen sensitization profiles have been described between these two risk groups. OBJECTIVE To investiga...

متن کامل

Hev b 5 and Hev b 13 as allergen markers to estimate the allergenic potency of latex gloves.

BACKGROUND Sensitization to natural rubber latex has been linked to proteins from medical latex gloves. Various assays to estimate the amount of residual allergenic proteins extractable from latex gloves to assess their potential exposure hazard have inherent weaknesses. OBJECTIVE This investigation was aimed at developing 2-site immunoenzymetric assays and identifying appropriate protein mar...

متن کامل

Anaphylaxis caused by latex surgical gloves immediately after starting surgery -A case report-

Anaphylaxis is an acute and fatal systemic allergic reaction to an allergen, and it can be an unpredictable and life-threatening cause during anesthesia. Latex is the second most common cause of anaphylaxis following the use of neuromuscular blocking agents during general anesthesia or surgery. We report on a 67-year-old male who had undergone surgery under general anesthesia without any proble...

متن کامل

Anaphylaxis to latex during surgery.

Five young women, all of whom had anaphylactic responses in operating units, are described. Three of them worked in a hospital three showed immediate hypersensitivity to fruit and all had known urticaria to latex. Anaphylaxis appeared progressively 15 to 30 minutes after injection of anaesthetic drugs. Skin tests with these drugs were negative. Skin prick tests through gloves and with four diff...

متن کامل

مقایسه تأثیر استفاده از دستکش لاتکس و نیتریل بر مهارت دست در جمعیت ایرانی

Introduction: Manual dexterity impairment due to wearing latex and nitrile gloves among health care employees and laboratory personnel can be a remarkable problem because of its adverse outcomes. The present study was conducted to “compare the effect of using latex and nitrile laboratory gloves on hand dexterity”. .Material and Method: In a semi experimental study design, 30 university were s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Allergologia et immunopathologia

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2006