Arrhythmia/Electrophysiology Agreement Is Poor Among Current Criteria Used to Define Response to Cardiac Resynchronization Therapy

نویسندگان

  • Brandon K. Fornwalt
  • William W. Sprague
  • Jonathan D. Suever
  • John D. Merlino
  • Derek A. Fyfe
  • John N. Oshinski
چکیده

Background—Numerous criteria believed to define a positive response to cardiac resynchronization therapy have been used in the literature. No study has investigated agreement among these response criteria. We hypothesized that the agreement among the various response criteria would be poor. Methods and Results—A literature search was conducted with the keywords “cardiac resynchronization” and “response.” The 50 publications with the most citations were reviewed. After the exclusion of editorials and reviews, 17 different primary response criteria were identified from 26 relevant articles. The agreement among 15 of these 17 response criteria was assessed in 426 patients from the Predictors of Response to Cardiac Resynchronization Therapy (PROSPECT) study with Cohen’s -coefficient (2 response criteria were not calculable from PROSPECT data). The overall response rate ranged from 32% to 91% for the 15 response criteria. Ninety-nine percent of patients showed a positive response according to at least 1 of the 15 criteria, whereas 94% were classified as a nonresponder by at least 1 criterion. -Values were calculated for all 105 possible comparisons among the 15 response criteria and classified into standard ranges: Poor agreement ( 0.4), moderate agreement (0.4 0.75), and strong agreement ( 0.75). Seventy-five percent of the comparisons showed poor agreement, 21% showed moderate agreement, and only 4% showed strong agreement. Conclusions—The 26 most-cited publications on predicting response to cardiac resynchronization therapy define response using 17 different criteria. Agreement between different methods to define response to cardiac resynchronization therapy is poor 75% of the time and strong only 4% of the time, which severely limits the ability to generalize results over multiple studies. (Circulation. 2010;121:1985-1991.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Agreement is poor among current criteria used to define response to cardiac resynchronization therapy.

BACKGROUND Numerous criteria believed to define a positive response to cardiac resynchronization therapy have been used in the literature. No study has investigated agreement among these response criteria. We hypothesized that the agreement among the various response criteria would be poor. METHODS AND RESULTS A literature search was conducted with the keywords "cardiac resynchronization" and...

متن کامل

Many response criteria are poor predictors of outcomes after cardiac resynchronization therapy: validation using data from the randomized trial.

AIMS The aim of the study was to assess the predictive value for outcomes of various response criteria currently used in patients undergoing cardiac resynchronization therapy (CRT). METHODS AND RESULTS Data from TRUST CRT randomized trial in patients with New York Heart Association (NYHA) III-IV class, QRS ≥ 120 ms, ejection fraction ≤ 35%, and mechanical dyssynchrony was analysed. Ninety-sev...

متن کامل

January 8th Question.

A 78-year-old man presents to establish care on his implanted cardiac resynchronization therapy–defibrillator. He has history of permanent atrial fibrillation, ischemic cardiomyopathy, left bundle branch block, and chronic New York Heart Association functional class III congestive heart failure. He had primary prevention cardiac resynchronization therapy–defibrillator implanted 2 years ago and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010