Invasive assessment of the coronary microcirculation using the index of microcirculatory resistance: description and validation of an animal model.
نویسندگان
چکیده
INTRODUCTION The index of microcirculatory resistance (IMR) enables/provides quantitative, invasive, and real-time assessment of coronary microcirculation status. AIMS The primary aim of this study was to validate the assessment of IMR in a large animal model, and the secondary aim was to compare two doses of intracoronary papaverine, 5 and 10 mg, for induction of maximal hyperemia and its evolution over time. METHODS Measurements of IMR were performed in eight pigs. Mean distal pressure (Pd) and mean transit time (Tmn) were measured at rest and at maximal hyperemia induced with intracoronary papaverine, 5 and 10 mg, and after 2, 5, 8 and 10 minutes. Disruption of the microcirculation was achieved by selective injection of 40-μm microspheres via a microcatheter in the left anterior descending artery. RESULTS In each animal 14 IMR measurements were made. There were no differences between the two doses of papaverine regarding Pd response and IMR values - 11 ± 4.5 U with 5 mg and 10.6 ± 3 U with 10 mg (p=0.612). The evolution of IMR over time was also similar with the two doses, with significant differences from resting values disappearing after five minutes of intracoronary papaverine administration. IMR increased with disrupted microcirculation in all animals (41 ± 16 U, p=0.001). CONCLUSIONS IMR provides invasive and real-time assessment of coronary microcirculation. Disruption of the microvascular bed is associated with a significant increase in IMR. A 5-mg dose of intracoronary papaverine is as effective as a 10-mg dose in inducing maximal hyperemia. After five minutes of papaverine administration there is no significant difference from resting hemodynamic status.
منابع مشابه
Intracoronary Delivery of Human Mesenchymal/Stromal Stem Cells: Insights from Coronary Microcirculation Invasive Assessment in a Swine Model
BACKGROUND Mesenchymal stem/stromal cells have unique properties favorable to their use in clinical practice and have been studied for cardiac repair. However, these cells are larger than coronary microvessels and there is controversy about the risk of embolization and microinfarctions, which could jeopardize the safety and efficacy of intracoronary route for their delivery. The index of microc...
متن کاملNovel index for invasively assessing the coronary microcirculation.
BACKGROUND A relatively simple, invasive method for quantitatively assessing the status of the coronary microcirculation independent of the epicardial artery is lacking. METHODS AND RESULTS By using a coronary pressure wire and modified software, it is possible to calculate the mean transit time of room-temperature saline injected down a coronary artery. The inverse of the hyperemic mean tran...
متن کاملAssessment of microcirculatory remodeling with intracoronary flow velocity and pressure measurements: validation with endomyocardial sampling in cardiac allografts.
BACKGROUND Intracoronary physiology techniques have been validated extensively for the assessment of epicardial stenoses but not for the lone study of coronary microcirculation. We performed a comparison between 4 intracoronary physiological indices with the actual structural microcirculatory changes documented in transplanted hearts. METHODS AND RESULTS In 17 cardiac allograft patients witho...
متن کاملMagnetic Resonance for Noninvasive Detection of Microcirculatory Disease Associated With Allograft Vasculopathy: Intracoronary Measurement Validation.
INTRODUCTION AND OBJECTIVES Cardiac allograft vasculopathy affects both epicardial and microcirculatory coronary compartments. Magnetic resonance perfusion imaging has been proposed as a useful tool to assess microcirculation mostly outside the heart transplantation setting. Instantaneous hyperemic diastolic flow velocity-pressure slope, an intracoronary physiology index, has demonstrated a bet...
متن کاملInvasive assessment of the coronary microcirculation: superior reproducibility and less hemodynamic dependence of index of microcirculatory resistance compared with coronary flow reserve.
BACKGROUND A simple, reproducible invasive method for assessing the coronary microcirculation is lacking. A novel index of microcirculatory resistance (IMR) has been shown in animals to correlate with true microvascular resistance and, unlike coronary flow reserve (CFR), to be independent of the epicardial artery. We sought to compare the reproducibility and hemodynamic dependence of IMR with C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2014