Small Animal Simulation Studies using the microPET® FOCUS System and the GATE Platform
نویسندگان
چکیده
GATE, a Monte Carlo simulation platform dedicated to nuclear medicine, has been validated for modeling μPET systems like the microPET® FOCUS 220 under realistic imaging conditions. In this paper, the use of the microPET® FOCUS 220 simulation model with GATE is used along with realistic mouse phantoms (including respiratory motion) and radioactive distribution maps, obtained from real exams, to produce simulated PET data of a mouse. We present results from simulated realistic whole body studies of the mouse with [18F]fluoride and 2-Deoxy-[18F]fluoro-D-glucose (FDG) and compare them to real data. The simulations were performed using voxelized mouse phantoms, obtained from real PET examinations and from digital mouse anatomical models. Respiratory motion is introduced in the simulation process. The qualitative and quantitative results from simulated data reproduce real values within 23%. This discrepancy can be related with specificities of simulated and real data, in particular due to attenuation and scattering corrections.
منابع مشابه
Field Programmable Gate Array–based Implementation of an Improved Algorithm for Objects Distance Measurement (TECHNICAL NOTE)
In this work, the design of a low-cost, field programmable gate array (FPGA)-based digital hardware platform that implements image processing algorithms for real-time distance measurement is presented. Using embedded development kit (EDK) tools from Xilinx, the system is developed on a spartan3 / xc3s400, one of the common and low cost field programmable gate arrays from the Xilinx Spartan fami...
متن کاملPerformance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...
متن کاملPerformance evaluation of the microPET focus: a third-generation microPET scanner dedicated to animal imaging.
UNLABELLED The microPET Focus is the latest generation microPET system dedicated to high-resolution animal imaging and incorporates several changes to enhance its performance. This study evaluated the basic performance of the scanner and compared it with the Primate (P4) and Rodent (R4) models. METHODS The system consists of 168 lutetium oxyorthosilicate (LSO) detectors arranged in 4 contiguo...
متن کاملAutomatic Landing of Small Helicopters on 4 DOF Moving Platforms
In this research, an automatic control system is designed for landing of a small helicopter on a 4 DOF moving platform. The platform has three translational and one directional degree of freedom. The controller design approach is based on development of helicopter nonlinear dynamic model into the SDC (State Dependent Coefficient) form and real time solving of state dependent Riccati equation (S...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016