Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic ‘ball-and-socket’ joint model

نویسندگان

  • L. Ernstbrunner
  • J-D. Werthel
  • T. Hatta
  • A. R. Thoreson
  • H. Resch
  • K-N. An
  • P. Moroder
چکیده

OBJECTIVES The bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo. METHODS Four polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius. RESULTS The experimental SR is comparable with the calculated SR (mean difference 10%, sd 8%; relative values). The experimental incongruence study observed almost no differences (2%, sd 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, sd 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, sd 55%). CONCLUSION The present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended.Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H. Resch, K-N. An, P. Moroder. Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic 'ball-and-socket' joint model. Bone Joint Res 2016;5:453-460. DOI: 10.1302/2046-3758.510.BJR-2016-0078.R1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model Predictive Control and Stability Analysis of a Standing Biped with Toe-Joint

In this paper standing balance control of a biped with toe-joint is presented. The model consists of an inverted pendulum as the upper body and the foot contains toe-joint. The biped is actuated by two torques at ankle-joint and toe-joint to regulate the upper body in upright position. To model the interaction between foot and the ground, configuration constraints are defined and utilized. To s...

متن کامل

The Stabilising Effect of the Anterior Oblique Ligament to Prevent Directional Subluxation at the Trapeziometacarpal Joint of the Thumb: A Biomechanical Cadaveric Study

Background: The trapeziometacarpal joint (TMCJ) is inherently unstable, relying on ligament restraint to preventsubluxation. Subluxation of the thumb in a dorsoradial direction is often observed in clinical practice, either after acuteligament injury or more commonly with osteoarthritis (OA). This subluxation follows loss of function of trapeziometacarpalligaments that stabilise this joint, res...

متن کامل

Effect of exercise therapy with Beta medicine ball on directed and general co-contraction of ankle joint muscles in low back pain patients during walking

Introduction and aim: In the past few decades, exercise has been promoted with increasing interest for the treatment of back pain. Therefore, the present study aimed to investigate the effect of rehabilitation exercises with medicine beta balls on the directional and general contraction of ankle joint muscles in patients with low back pain during walking. Methods: The present study was a clini...

متن کامل

The Effect of Inclined U-Notch Geometry on Mode Ratio (KII/KI) under Mixed Mode (I + II) Loading

In inclined U-notches, the mixed mode (I + II) loading occurs and the mode ratio can be increased by varying the notch angle. In this paper, the effect of the inclined U-notch geometry, i.e. the notch depth, the notch angle, the notch root radius, and the position of the notch with respect to supports, on the mode ratio (KII/KI) have been studied. Three-point bending and plane strain condition ...

متن کامل

Analytical and Numerical Investigation of Significant Parameters on Strength of Electromagnetically Assembled Products Joints

Electromagnetic forming is a high energy rate forming process. In this process, an electromagnetic Lorentz body force is used for deformation of products. In this article, Electromagnetic forming process was simulated for assembly of parts as an innovative method. In this research work, the effect of important parameters of process such as discharge energy, radius and width of rectangular groov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016